S 012-113
(2)
AIRPLANES WITHOUT A DOOR 5 OVERHEAD CREW REST COMPARTMENT; Open the access panel for the aft equipment center near door 5.
S 022-120
(3)
Remove the ULB from the flight data recorder:
(a)
Loosen the two screws on one beacon mounting bracket (the bracket stays attached).
(b)
Remove the two screws from the other beacon mounting bracket.
(c)
Remove the ULB from the brackets.
(d)
Keep the two screws and the beacon mounting bracket.
TASK 31-31-09-962-004
3. FLIGHT DATA RECORDERS WITH DUKANE ULBs; Underwater Locator Beacon Battery Replacement (Fig. 202)_____________________________________________
A. General
(1) Do not replace the battery in the DK100 underwater locator beacon (ULB). On or before the expired date, send the DK100 to the manufacturer for servicing.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
31-31-09
ALL ú ú 13 Page 201 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
BATTERY REPLACE-BY-DATE DECAL
A
Underwater Locator Beacon Unit Removal/Installation
Figure 201
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
31-31-09
ALL ú ú 26 Page 202 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
L42757
A
747-400
MAINTENANCE MANUAL
B. Equipment
(1)
Spanner Wrench, 810-325
Dukane Corporation
2900 Dukane Drive
St. Charles, IL 60174
(2)
Split Radiator Hose
-1-1/4-inch diameter, 5 inches in length
C. Consumable Materials
(1)
D00318 Lubricant, Dukane 810-346
(2)
G02440 Battery, Dukane 810-2007K
(3)
G00751 O-ring, Dukane 810-342
(4)
G01523 Lubricated O-ring, Datasonics 2-022
D. Removal Procedure
SHOCK CUSHION
SPANNER WRENCH
LOCATOR BEACON
BATTERY INSTALLATION
Underwater Locator Beacon Unit Battery Replacement Figure 202
A75546
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
31-31-09
ALL ú ú 01 Page 203 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
S 512-007
WARNING:_______DO NOT REMOVE THE BATTERY FROM THE DK100 ULB. DO NOT CAUSE DAMAGE TO THE DK100 ULB. DO NOT DISCARD THE DK100 ULB. THE MANUFACTURER HAS A REPLACEMENT PROGRAM FOR EXPIRED ULBs. ON OR BEFORE THE EXPIRED DATE, SEND THE DK100 ULB TO THE MANUFACTURER FOR SERVICING. THE BATTERY CONTAINS DANGEROUS CHEMICAL MATERIALS WHICH CAN CAUSE INJURIES TO PERSONNEL.
(1)
If you have a DK100 ULB, send the ULB to the manufacturer for servicing.
S 022-054
(2)
If you do not have a DK100 ULB, remove the ULB battery:
CAUTION: DO NOT HOLD THE UNDERWATER LOCATOR BEACON WITH A VISE.
_______ THIS CAN CAUSE DAMAGE TO THE UNDERWATER LOCATOR BEACON.
(a)
Hold the ULB with a split radiator hose.
(b)
Use a spanner wrench to remove the end cap that is identified as BATTERY ACCESS.
(c)
Remove the rubber shock cushion from the battery end if it is not removed with the end cap.
(d)
Hit the ULB body lightly to remove the battery.
E. Installation Procedure
S 422-008
(1) Install the new ULB battery:
NOTE: The Dukane 810-2007K battery is a 6 year lithium battery used
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 指示/记录系统 1(60)