R  121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 
R  121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05 
R  Subtask 52-73-11-010-055 
R  C. Get Access 
R  WARNING : STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES._______ 
R  RESIDUAL PRESSURE COULD CAUSE THE DOOR TO OPEN WITH A SUDDEN 
R  FORCE AND INJURE PERSONS AND/OR DAMAGE THE AIRCRAFT. 
R  (1) Put an access platform in position at the applicable emergency exit 
R  834 or 844. 
R  (2) Open the applicable emergency exit 834 or 844 (Ref. TASK 52-22-00-
R  010-002). 
R  (3) Obey the special precautions before you start work on the emergency 
R  exit (Ref. TASK 52-22-00-860-003). 
R  Subtask 52-73-11-010-063 
R  D. Removal of the Lining Panel 
R  (1) Remove the lining panel: 
R  FOR 6WN1 
R  834CZ (Ref. TASK 25-23-47-000-013). 
R  FOR 6WN2 
R  844CZ (Ref. TASK 25-23-47-000-013). 
R  (2) Remove the insulation blanket. 

R 1EFF : 301-399, 1 52-73-11Page 438 1 1 May 01/04 1 1 1CES 1


R  4. Procedure_________ 
R  Subtask 52-73-11-020-059 
R  A. Removal of the Proximity Switch 
R  (Ref. Fig. 406/TASK 52-73-11-991-007) 
R  (1) Disconnect the electrical connector (1) from the proximity switch 
R  (2). 
R  (2) Put blanking caps on the disconnected electrical connectors. 
R  (3) Remove and discard the lockwire. 
R  (4) Remove the nut (4) and the washer (3). 
R  (5) Remove the proximity switch (2). 

R 1EFF : 301-399, 1 52-73-11Page 439 1 1 May 01/04 1 1 1CES 1R Proximity Switches (6WN1, 6WN2) of the Aft Emergency Exits R Figure 406/TASK 52-73-11-991-007


R 1EFF : 301-399, 1 52-73-11Page 440 1 1 May 01/04 1 1 1CES 1


R **ON A/C 151-199, 401-499,

 TASK 52-73-11-000-004-A
 Removal of the Proximity Switches (6WN1, 6WN2) of the Emergency Exits
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific blanking caps
 No specific circuit breaker(s) safety clip(s)
 No specific wrench
 No specific access platform 3.5 m (11 ft. 6 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
 Power 52-10-00-010-001 Opening of the Passenger/Crew Door 52-73-11-991-008 Fig. 407 FOR FIN 6WN1 25-23-47-000-002 Removal of the Upper Sidewall Panel Assy 241LW,
 (242LW), 241CW, (242CW) and 241FW, (242FW) FOR FIN 6WN2 25-23-47-000-002 Removal of the Upper Sidewall Panel Assy 241LW,
 (242LW), 241CW, (242CW) and 241FW, (242FW)
 3. Job Set-up
__________
 Subtask 52-73-11-861-058
 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

R 1EFF : 151-199, 401-499, 1 52-73-11Page 441 1 1 Aug 01/05 1 1 1CES 1 Subtask 52-73-11-010-056


 B. Get Access WARNING : DO NOT OPEN THE PASSENGER/CREW DOOR IF THE WIND SPEED IS MORE
_______
 THAN 65 KNOTS.

 WARNING : STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES.
_______ RESIDUAL PRESSURE COULD CAUSE THE DOOR TO OPEN WITH A SUDDEN FORCE AND INJURE PERSONS AND/OR DAMAGE THE AIRCRAFT.
 (1)
 Put an access platform in position in front of the applicable FWD passenger/crew door 831 or 841.

 (2)
 Open the applicable FWD passenger/crew door 831 or 841 (Ref. TASK 52-10-00-010-001).


 Subtask 52-73-11-865-071
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11 121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
 Subtask 52-73-11-010-064
 D. Disarming of the Escape Slide of the Emergency Exit
 (Ref. Fig. 407/TASK 52-73-11-991-008)
 