WARNING : DO NOT OPEN THE EMERGENCY EXIT DURING THE ADJUSTMENT.
_______
(1)
Make sure that the emergency exits are closed.
(2)
Disconnect the electrical connector (1) from the proximity switch (2).
(3)
Connect the CHECKING TOOL-DOORS (355M03210000) to the electrical connector of the proximity switch (2).
(4)
Remove and discard the lockwire from the nut (4).
(5)
Loosen the nut (4) of the target (3).
(6)
Turn the target (3) until the NEAR indicator light comes on. NOTE : The target (3) and the proximity switch (2) must not be in
____
contact.
(7)
Turn the target (2) in the opposite direction until the FAR indicator light comes on.
(8)
From this position, screw the target (3) by two turns to two turns and a half.
(9)
Tighten the nut (4).
(10) Safety the nut (4) with MISCELLANEOUS (Material No. 19-010).
1EFF : 301-399, 1 52-71-00Page A511 1 1 May 01/05R 1 1 1CES 1
Proximity Switches (5WN1, 5WN2, 6WN1, 6WN2) - Emergency Exits Figure 516/TASK 52-71-00-991-017
1EFF : 301-399, 1 52-71-00Page A512 1 1 May 01/05R 1 1 1CES 1
(11) Disconnect the CHECKING TOOL-DOORS (355M03210000) from the proximity
switch.
(12) Connect the electrical connector (1) to the proximity switch (2). Subtask 52-71-00-865-068
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 48WV, 13WN, 15WN
Subtask 52-71-00-710-066
C. Operational Test
(1) Do an operational test of the warning system related to the emergency exits (Ref. TASK 52-73-00-710-002).
5. Close-up
________ Subtask 52-71-00-410-083
A. Installation of the Lining Panel
(1)
Install the insulation blanket.
(2)
Install the lining panel:
FOR 5WN1
833CZ, (Ref. TASK 25-23-47-400-012).
FOR 5WN2
843CZ, (Ref. TASK 25-23-47-400-013).
FOR 6WN1
834CZ, (Ref. TASK 25-23-47-400-013).
FOR 6WN2
844CZ, (Ref. TASK 25-23-47-400-013).
1EFF : 301-399, 1 52-71-00Page A513 1 1 May 01/05R 1 1 1CES 1
Subtask 52-71-00-410-084
B. Close Access
(1)
Obey the special precautions after the work on the emergency exit (Ref. TASK 52-22-00-860-004).
(2)
Make sure that the work area is clean and clear of tool(s) and other items.
(3)
Close the applicable emergency exit 833 or 834 or 843 or 844, (Ref. TASK 52-22-00-410-002).
(4) Remove the access platform(s). Subtask 52-71-00-862-066
C. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
1EFF : 301-399, 1 52-71-00Page A514 1 1 May 01/05R 1 1 1CES 1
TASK 52-71-00-820-009-B01
Adjustment of the Proximity Switches (5WN1, 5WN2, 6WN1, 6WN2) of the Emergency Exits with the ECAM DU
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 3.50 m (11 ft. 6 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 19-010 USA AMS 5687 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 52-22-00-010-002 Opening of the Emergency Exit Doors from the Outside 52-22-00-410-001 Closing of the Emergency Exit Doors from the
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(26)