C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
Power
24-42-00-862-001 De-energize the Ground Service Network Supplied from
the External Power
52-22-00-010-002 Opening of the Emergency Exit Doors from the Outside
52-22-00-410-001 Closing of the Emergency Exit Doors from the
Passenger Compartment
52-22-00-410-002 Closing of the Emergency Exit Doors from the Outside
52-22-00-860-003 Special Precaution before Maintenance on the Door
Damper and Emergency Operation Cylinder
52-22-00-860-004 Special Precaution after Maintenance on the Door
Damper and Emergency Operation Cylinder
52-73-00-710-002 Operational Test of the Warning System related to the
Emergency Exits
52-71-00-991-017 Fig. 516
FOR FIN 5WN1
25-23-47-000-012 Removal of the Door Linings of the LH FWD Emergency
Exit Door, zone 231
25-23-47-400-012 Installation of the Door Linings of the LH FWD
Emergency Exit Door, zone 231
FOR FIN 5WN2
25-23-47-000-013 Removal of the Door Linings of the RH FWD Emergency
Exit Door at zone 251 or RH AFT at zone 252 or LH AFT
at zone 232.
25-23-47-400-013 Installation of the Door Linings of the RH FWD
Emergency Exit Door at zone 251, or RH AFT at zone
252, or LH AFT at zone 232.
FOR FIN 6WN1
25-23-47-000-013 Removal of the Door Linings of the RH FWD Emergency
Exit Door at zone 251 or RH AFT at zone 252 or LH AFT
at zone 232.
25-23-47-400-013 Installation of the Door Linings of the RH FWD
Emergency Exit Door at zone 251, or RH AFT at zone
252, or LH AFT at zone 232.
FOR FIN 6WN2
25-23-47-000-013 Removal of the Door Linings of the RH FWD Emergency
Exit Door at zone 251 or RH AFT at zone 252 or LH AFT
at zone 232.
25-23-47-400-013 Installation of the Door Linings of the RH FWD
Emergency Exit Door at zone 251, or RH AFT at zone
252, or LH AFT at zone 232.
1EFF : 301-399, 1 52-71-00Page A509 1 1 May 01/05R 1 1 1CES 1
3. Job Set-up
__________ Subtask 52-71-00-861-065
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
Subtask 52-71-00-010-079
B. Get Access WARNING : STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES.
_______ RESIDUAL PRESSURE COULD CAUSE THE DOOR TO OPEN WITH A SUDDEN FORCE AND INJURE PERSONS AND/OR DAMAGE THE AIRCRAFT.
(1)
Put an access platform in position at the applicable emergency exit 833 or 834 or 843 or 844.
(2)
Open the applicable emergency exit 833 or 834 or 843 or 844, (Ref. TASK 52-22-00-010-002).
(3)
Obey the special precautions before you start work on the emergency exit (Ref. TASK 52-22-00-860-003).
(4)
Close the applicable emergency exit 833 or 834 from the inside (Ref. TASK 52-22-00-410-001).
Subtask 52-71-00-010-080
C. Removal of the Lining Panel
(1) Remove the lining panel:
FOR 5WN1
833CZ, (Ref. TASK 25-23-47-000-012).
FOR 5WN2
843CZ, (Ref. TASK 25-23-47-000-013).
FOR 6WN1
834CZ, (Ref. TASK 25-23-47-000-013).
FOR 6WN2
844CZ, (Ref. TASK 25-23-47-000-013).
(2) Remove the insulation blanket.
1EFF : 301-399, 1 52-71-00Page A510 1 1 May 01/05R 1 1 1CES 1
Subtask 52-71-00-865-067
D. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------