C. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001  Energize the Ground Service Network from the External 
 Power 
 24-42-00-862-001  De-energize the Ground Service Network Supplied from 
 the External Power 
 52-22-00-010-002  Opening of the Emergency Exit Doors from the Outside 
 52-22-00-410-001  Closing of the Emergency Exit Doors from the 
 Passenger Compartment 
 52-22-00-410-002  Closing of the Emergency Exit Doors from the Outside 
 52-22-00-860-003  Special Precaution before Maintenance on the Door 
 Damper and Emergency Operation Cylinder 
 52-22-00-860-004  Special Precaution after Maintenance on the Door 
 Damper and Emergency Operation Cylinder 
 52-73-00-710-002  Operational Test of the Warning System related to the 
 Emergency Exits 
 52-71-00-991-017  Fig. 516 
 FOR FIN 5WN1 
 25-23-47-000-012  Removal of the Door Linings of the LH FWD Emergency 
 Exit Door, zone 231 
 25-23-47-400-012  Installation of the Door Linings of the LH FWD 
 Emergency Exit Door, zone 231 
 FOR FIN 5WN2 
 25-23-47-000-013  Removal of the Door Linings of the RH FWD Emergency 
 Exit Door at zone 251 or RH AFT at zone 252 or LH AFT 
 at zone 232. 
 25-23-47-400-013  Installation of the Door Linings of the RH FWD 
 Emergency Exit Door at zone 251, or RH AFT at zone 
 252, or LH AFT at zone 232. 
 FOR FIN 6WN1 
 25-23-47-000-013  Removal of the Door Linings of the RH FWD Emergency 
 Exit Door at zone 251 or RH AFT at zone 252 or LH AFT 
 at zone 232. 
 25-23-47-400-013  Installation of the Door Linings of the RH FWD 
 Emergency Exit Door at zone 251, or RH AFT at zone 
 252, or LH AFT at zone 232. 
 FOR FIN 6WN2 
 25-23-47-000-013  Removal of the Door Linings of the RH FWD Emergency 
 Exit Door at zone 251 or RH AFT at zone 252 or LH AFT 
 at zone 232. 
 25-23-47-400-013  Installation of the Door Linings of the RH FWD 
 Emergency Exit Door at zone 251, or RH AFT at zone 
 252, or LH AFT at zone 232.
1EFF : 301-399, 1 52-71-00Page A509 1 1 May 01/05R 1 1 1CES 1
 3. Job Set-up
__________ Subtask 52-71-00-861-065
 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).
 Subtask 52-71-00-010-079
 B. Get Access WARNING : STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES.
_______ RESIDUAL PRESSURE COULD CAUSE THE DOOR TO OPEN WITH A SUDDEN FORCE AND INJURE PERSONS AND/OR DAMAGE THE AIRCRAFT.
 (1)
 Put an access platform in position at the applicable emergency exit 833 or 834 or 843 or 844.
 (2)
 Open the applicable emergency exit 833 or 834 or 843 or 844, (Ref. TASK 52-22-00-010-002).
 (3)
 Obey the special precautions before you start work on the emergency exit (Ref. TASK 52-22-00-860-003).
 (4)
 Close the applicable emergency exit 833 or 834 from the inside (Ref. TASK 52-22-00-410-001).
 Subtask 52-71-00-010-080
 C. Removal of the Lining Panel
 (1) Remove the lining panel:
 FOR 5WN1
 833CZ, (Ref. TASK 25-23-47-000-012).
 FOR 5WN2
 843CZ, (Ref. TASK 25-23-47-000-013).
 FOR 6WN1
 834CZ, (Ref. TASK 25-23-47-000-013).
 FOR 6WN2
 844CZ, (Ref. TASK 25-23-47-000-013).
 (2) Remove the insulation blanket.
 1EFF : 301-399, 1 52-71-00Page A510 1 1 May 01/05R 1 1 1CES 1
 Subtask 52-71-00-865-067
 D. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(25)