the SLIDE ARMED indicator light (21WN1) goes off.
-
the symbol of the forward left emergency exit becomes green. The EMERGENCY message goes out of view.
R A. Remove the safety clip(s) and the tag(s) and close this(these) circuit R breaker(s): R 1WL, 2WL, 3WL 
R Subtask 52-73-00-860-058 
R B. Put the aircraft back to its initial configuration. 
R (1) Do an EIS stop procedure (Ref. TASK 31-60-00-860-002). 
R 1EFF : 301-399, 1 52-73-00Page 516 1 1 May 01/04 1 1 1CES 1
R  Subtask 52-73-00-941-052  
R  C. Close Access  
R  (1) Make sure that the work area is clean and clear of tool(s) and other  
R  items.  
R  (2) Obey the special precautions after the work on the emergency exit  
R  (Ref. TASK 52-22-00-860-004).  
R  (3) Close the emergency exit (Ref. TASK 52-22-00-410-002).  
R  (4) Remove the access platform(s).  
R  Subtask 52-73-00-862-055  
R  D. De-energize the aircraft electrical circuits  
R  (Ref. TASK 24-41-00-862-002). 
R 1EFF : 301-399, 1 52-73-00Page 517 1 1 May 01/04 1 1 1CES 1R **ON A/C 151-199, 401-499,
 TASK 52-73-00-710-002-A
 Operational Test of the Warning System Related to the Emergency Exits
 1.
 Reason for the Job
__________________
 Self Explanatory
 2.
 Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power
 31-60-00-860-001 EIS Start Procedure
 31-60-00-860-002 EIS Stop Procedure
 52-73-00-991-002 Fig. 502
 3. Job Set-up
__________
 Subtask 52-73-00-861-056
 A. Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).
R 1EFF : 151-199, 401-499, 1 52-73-00Page 518 1 1 Aug 01/05 1 1 1CES 1 Subtask 52-73-00-860-052
 B. Aircraft Maintenance Configuration
 (1)
 Do an EIS start procedure (Ref. TASK 31-60-00-860-001).
 (2)
 On the ECAM control panel, push the DOOR key (on the lower ECAM display unit, the DOOR/OXY page comes into view).
 Subtask 52-73-00-865-066
 C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------
PANEL ------ DESIGNATION ------------------------------------------------------- IDENT. LOCATION------------------ 
121VU EIS/SLIDES/ARM AND WARN/FLT  15WN  P11 
 121VU EIS/SLIDES/ARM AND WARN/GND  13WN  P10 
 Subtask 52-73-00-865-067 
 D. Open, safety and tag this(these) circuit breaker(s): 
 ------PANEL  -------------------------------------------------------DESIGNATION  ------------------IDENT. LOCATION
 -------------------------------------------------------------------------------49VU LIGHTING/EMER LT/CABIN 2WL H06 49VU LIGHTING/EMER LT/CABIN 1WL H05
 122VU LIGHTING/CABIN/EMER/LT 3WL V07 
R 1EFF : 151-199, 401-499, 1 52-73-00Page 519 1 1 Aug 01/05 1 1 1CES 1
 4. Procedure
_________ Subtask 52-73-00-710-056
 A. Operational Test of the Warning System Related to the Emergency Exit (Ref. Fig. 502/TASK 52-73-00-991-002)
 (1) Do the test below:
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the hatch (left emergency exit): 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(63)