R 1EFF : ALL 1 52-71-12Page 421 1 1 May 01/05 1 1 1CES 1
D. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-71-00-820-003 Adjustment of the Proximity Switches 30WV and 32WV of the Cargo Compartment Door Threshold
**ON A/C 001-049, 051-099, 101-105, 201-220,
52-71-12-991-002 Fig. 402
R **ON A/C 106-149, 221-299, 301-399, 401-499,
52-71-12-991-002-B Fig. 402A
**ON A/C 151-199,
52-71-12-991-002-A Fig. 402B
**ON A/C ALL
3. Job Set-up
__________
**ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
Subtask 52-71-12-860-053
A. Get Access
(1)
Make sure that the the applicable cargo door is opened (Ref. TASK 52-30-00-860-001).
(2)
Make sure that the access platform is in position for the applicable cargo door.
1EFF : ALL 1 52-71-12Page 422 1 1 Aug 01/05 1 1 1CES 1
(3) Make sure that the access panel(s) 825AR and/or 826AR are removed.
R **ON A/C 151-199, 401-499,
Subtask 52-71-12-860-053-A
A. Get Access
(1)
Make sure that the the applicable cargo door is opened (Ref. TASK 52-30-00-860-001).
(2)
Make sure that the access platform is in position for the applicable cargo door.
(3)
Make sure that the access panel(s) 825AR and/or 826AR 826BR and 826CR are removed.
**ON A/C ALL
Subtask 52-71-12-865-054
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU L/G/LGCIU/SYS1/NORM 1GA C09 122VU DOORS/CARGO 1MJ T12
4. Procedure
_________
**ON A/C 001-049, 051-099, 101-105, 201-220,
(Ref. Fig. 402/TASK 52-71-12-991-002) R **ON A/C 106-149, 221-299, 301-399, 401-499,
(Ref. Fig. 402A/TASK 52-71-12-991-002-B)
1EFF : ALL 1 52-71-12Page 423 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 151-199,
R (Ref. Fig. 402B/TASK 52-71-12-991-002-A) **ON A/C ALL
Subtask 52-71-12-910-050
A. Preparation for the Installation
(1)
Make sure that the parts retained from the removed component are clean and in the correct condition.
(2)
Do an inspection of the component interface and/or the adjacent area.
(3)
Make sure that the electrical connectors are clean and in the correct condition.
(4)
Apply SEALANTS (Material No. 09-013) to the contact area of the proximity sensor (23) and the fuselage fitting (24).
(5)
Apply SEALANTS (Material No. 09-013) to the contact area between the target (31) and the target lever (32).
Subtask 52-71-12-420-051
B. Installation of the Proximity Switch
(1) Install the proximity sensor (23) as follows:
(a)
Put the proximity sensor (23) in position of the fuselage fitting (24).
(b)
Install the screws (22), the washers (25) and the nuts (26) and tighten them.
(c)
Remove the blanking caps from the electrical connector (21) and the receptacle of the proximity sensor (23).
(d)
Install the electrical connector (21) on the proximity sensor (23).
R 1EFF : ALL 1 52-71-12Page 424 1 1 May 01/05 1 1 1CES 1
(2) Install the target (31) as follows:
(a)
Put the target (31) in position of the target lever (32).
(b)
Install the screws (30), the washers (33) and the nuts (34) and tighten them.
Subtask 52-71-12-820-051
C. Adjustment of the Proximity Switch
(1)
Close the applicable cargo door (Ref. TASK 52-30-00-860-002).
(2)
Measure the clearance between the target (31) and the related proximity sensor (23).
NOTE : The clearance must be between 1.5 mm (0.0590 in.) and 2.0 mm
____
(0.0787 in.).
(3) If the clearance is out of tolerance, adjust the length of the link assy (38) as follows: 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(42)