(4)
Remove and discard the lockwire from the nut (4).
(5)
Loosen the nut (4) of the target (3).
(6)
Turn the target (3) until the indicator light comes on. NOTE : The target (3) and the proximity switch (2) must not be in
____
contact.
(7)
Turn the target (2) in the opposite direction until the FAR indicator light comes on.
(8)
From this position, screw the target (3) by two turns to two turns and a half.
1EFF : 301-399, 1 52-71-00Page 570 1 1 May 01/05R 1 1 1CES 1
Proximity Switches (59WV1, 59WV2, 61WV1, 61WV2) of the Emergency Exit Figure 509/TASK 52-71-00-991-011
1EFF : 301-399, 1 52-71-00Page 571 1 1 May 01/05R 1 1 1CES 1
(9) Tighten the nut (4) and safety it with MISCELLANEOUS (Material No. 19-010).
(10) Disconnect the CHECKING TOOL-DOORS (355M03210000) from the proximity switch.
(11) Connect the electrical connector (1) to the proximity switch (2). Subtask 52-71-00-710-061
B. Operational Test
(1) Do an operational test of the warning system related to the emergency exits (Ref. TASK 52-71-00-710-001).
5. Close-up
________ Subtask 52-71-00-410-074
A. Installation of the Lining Panel
(1)
Install the insulation blanket.
(2)
Install the lining panel:
FOR 59WV1
231NX.
FOR 59WV2
232NX.
FOR 61WV1
251MX.
FOR 61WV2
252MX.
Subtask 52-71-00-410-067
B. Close Access
(1)
Obey the special precautions after the work on the emergency exit (Ref. TASK 52-22-00-860-004).
(2)
Make sure that the work area is clean and clear of tool(s) and other items.
(3)
Close the applicable emergency exit 833 or 843 or 834 or 844 (Ref. TASK 52-22-00-410-002).
(4)
Remove the access platform(s).
1EFF : 301-399, 1 52-71-00Page 572 1 1 May 01/05R 1 1 1CES 1
Subtask 52-71-00-862-057
C. De-energize the ground service network (Ref. TASK 24-42-00-862-001)
1EFF : 301-399, 1 52-71-00Page 573 1 1 May 01/05R 1 1 1CES 1
TASK 52-71-00-820-005- 01
Adjustment of the Proximity Switches (59WV1,59WV2,61WV1,61WV2) of the Emergency Exit with the ECAM DU
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 3.2 m (10 ft. 6 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 19-010 USA AMS 5687 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 52-22-00-010-002 Opening of the Emergency Exit Doors from the Outside 52-22-00-410-002 Closing of the Emergency Exit Doors from the Outside 52-22-00-860-003 Special Precaution before Maintenance on the Door
Damper and Emergency Operation Cylinder 52-22-00-860-004 Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
1EFF : 301-399, 1 52-71-00Page 574 1 1 May 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-71-00-710-001 Operational Test of the Door Warning System 52-71-00-991-012 Fig. 510
3. Job Set-up
__________
Subtask 52-71-00-861-056
A. Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002)
Subtask 52-71-00-010-065
B. Get Access
(1)
Put an access platform in position at the applicable emergency exit 834 or 843 or 833 or 844.
(2) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(16)