R -------------------------------------------------------------------------------
R No specific circuit breaker(s) safety clip(s)
R No specific access platform 4.4 m (14 ft. 5 in.)

R B. Referenced Information

R -------------------------------------------------------------------------------R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R 24-41-00-861-002 R R 24-41-00-862-002 R R 31-60-00-860-001 R 31-60-00-860-002 R 52-22-00-010-002 R 52-22-00-410-001 R R 52-22-00-410-002 R 52-22-00-860-003 R R 52-22-00-860-004 R Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power EIS Start Procedure EIS Stop Procedure Opening of the Emergency Exit Doors from the Outside Closing of the Emergency Exit Doors from the Passenger Compartment Closing of the Emergency Exit Doors from the Outside Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
R 1EFF : 301-399, 1 52-73-00Page 513 1 1 May 01/04 1 1 1CES 1


R  3. Job Set-up__________ 
R  Subtask 52-73-00-861-055 
R  A. Energize the aircraft electrical circuits 
R  (Ref. TASK 24-41-00-861-002). 
R  Subtask 52-73-00-010-054 
R  B. Get Access 
R  (1) Put an access platform in position in front of the applicable 
R  emergency exit. 
R  (2) Open the applicable emergency exit (Ref. TASK 52-22-00-010-002). 
R  (3) Obey the special precautions before you start work on the emergency 
R  exit (Ref. TASK 52-22-00-860-003). 
R  (4) Close the applicable emergency (Ref. TASK 52-22-00-410-001). 
R  Subtask 52-73-00-860-059 
R  C. Aircraft Maintenance Configuration 
R  (1) Do an EIS start procedure (Ref. TASK 31-60-00-860-001). 
R  (2) Set the DOOR page. 
R  Subtask 52-73-00-865-063 
R  D. Make sure that this(these) circuit breaker(s) is(are) closed: 
R  -------------------------------------------------------------------------------
R  PANEL DESIGNATION IDENT. LOCATION 
R  -------------------------------------------------------------------------------
R  121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11 
R  121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 
R  121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05 

R 1EFF : 301-399, 1 52-73-00Page 514 1 1 May 01/04 1 1 1CES 1R Subtask 52-73-00-865-064


R E. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------R PANEL DESIGNATION IDENT. LOCATION R -------------------------------------------------------------------------------R 49VU LIGHTING/EMER LT/CABIN 2WL H06 R 49VU LIGHTING/EMER LT/CABIN 1WL H05 R 122VU LIGHTING/CABIN/EMER/LT 3WL V07
R 4. Procedure
_________ R Subtask 52-73-00-710-054 R A. Test the Warning System of the Emergency Exit R (1) Do the test below: R -------------------------------------------------------------------------------
R ACTION RESULT R -------------------------------------------------------------------------------
R 1. On the emergency control handle R of the forward left emergency R exit: R - remove the PIN - SAFETY SLIDE R (98A52107632000). R - put the handle in the ARMED R position. R R R
R 2. On the forward left emergency R exit, pull the inner control R handle until the visual indicator R is in the UNLOCKED position. R R R R R R
R 3. On the forward left emergency R exit door: On the lower ECAM display unit, on the DOOR/OXY page:
-
the symbol for the forward left emergency exit comes into view in green.

-
the SLIDE message comes into view in white. On the forward left emergengy exit:


-The SLIDE ARMED indicator light (21WN1) is off.
On the lower display ECAM display unit, on the DOOR/OXY page:
-
the EMERGENCY message and the symbol for the forward left emergency exit come into view in amber. The SLIDE message remains in view in white. On the forward left emergengy exit:

-
the SLIDE ARMED indicator light (21WN1) comes on.


On the lower ECAM display unit, on the DOOR/OXY page:
R 1EFF : 301-399, 1 52-73-00Page 515 1 1 May 01/04 1 1 1CES 1


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R - put the emergency control R handle in the DISARMED R position. Install the PIN -R SAFETY SLIDE (98A52107632000). R - push the inner control handle R of the door down until the R visual indicator is in the R LOCKED position.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(62)