R  (1) Remove the lining panel: 
R  FOR 5WN1 
R  833CZ (Ref. TASK 25-23-47-000-012). 
R  FOR 5WN2 
R  834CZ (Ref. TASK 25-23-47-000-013). 
R  (2) Remove the insulation blanket. 

R 1EFF : 301-399, 1 52-73-11Page 422 1 1 May 01/04 1 1 1CES 1


R  4. Procedure_________ 
R  Subtask 52-73-11-020-058 
R  A. Removal of the Proximity Switch 
R  (Ref. Fig. 404/TASK 52-73-11-991-006) 
R  (1) Disconnect the electrical connector (1) from the proximity switch 
R  (2). 
R  (2) Put blanking caps on the disconnected electrical connectors. 
R  (3) Remove and discard the lockwire. 
R  (4) Remove the nut (4) and the washer (3). 
R  (5) Remove the proximity switch (2). 

R 1EFF : 301-399, 1 52-73-11Page 423 1 1 May 01/04 1 1 1CES 1R Proximity Switches (5WN1, 5WN2) of the FWD Emergency Exits R Figure 404/TASK 52-73-11-991-006


R 1EFF : 301-399, 1 52-73-11Page 424 1 1 May 01/04 1 1 1CES 1R **ON A/C 001-049, 051-099, 101-149, 201-299,


 TASK 52-73-11-400-003
 Installation of the Proximity Switches (5WN1, 5WN2) of the FWD Emergency Exits
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific  wrench
 B. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
Material No. 19-010  USA AMS 5687
 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
 (Ref. 20-31-00)

 C. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from
 the External Power 52-10-00-410-001 Closing of the Passenger/Crew Door 52-71-00-820-009 Adjustment of the Proximity Switches (5WN1, 5WN2,
 6WN1, 6WN2) of the Emergency Exits 52-73-00-710-002 Operational Test of the Warning System related to the Emergency Exits 52-73-11-991-003 Fig. 403
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-73-11Page 425 1 1 May 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
FOR FIN 5WN2
 25-23-47-400-002 Installation of the Upper Sidewall Panel Assy 241LW,

 (242LW), 241CW, (242CW) and 241FW, (242FW) FOR FIN 5WN1 25-23-47-400-002 Installation of the Upper Sidewall Panel Assy 241LW,
 (242LW), 241CW, (242CW) and 241FW, (242FW)
 3. Job Set-up
__________ Subtask 52-73-11-860-055
 A. Aircraft Maintenance Configuration
 (1) Make sure that the ground service network is energized
 (Ref. TASK 24-42-00-861-001).

 (2) Make sure that the access platform is in position. Subtask 52-73-11-865-057
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11 121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
 4. Procedure
_________ Subtask 52-73-11-420-052
 A. Installation of the Proximity Switch
 (Ref. Fig. 403/TASK 52-73-11-991-003)

 (1)
 Install the proximity switch (2) on the support (3).

 (2)
 Install the washer (4) and the nut (5).

 (3)
 Tighten the nut (5). Safety it with MISCELLANEOUS (Material No. 19-010).


R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-73-11Page 426 1 1 May 01/05 1 1 1CES 1


 (4)
 Remove the blanking cap from the electrical connector (1).

 (5)
 Connect the electrical connector (1) to the proximity switch (2).


 (6) Adjust the proximity switch (2) (Ref. TASK 52-71-00-820-009). Subtask 52-73-11-865-058
 