Proximity Switches (19WV1, 19WV2, 21WV1, 21WV2) of the Emergency Exits Figure 511/TASK 52-71-00-991-013
1EFF : 301-399, 1 52-71-00Page 583 1 1 May 01/05R 1 1 1CES 1
Subtask 52-71-00-710-053
C. Operational Test
(1) Do an operational test of the warning system related to the emergency exits (Ref. TASK 52-71-00-710-001).
5. Close-up
________ Subtask 52-71-00-410-077
A. Installation of the Lining Panel
(1)
Install the insulation blanket.
(2)
Install the lining panel:
FOR 19WV1
833EZ (Ref. TASK 25-23-47-400-012).
FOR 19WV2
834EZ (Ref. TASK 25-23-47-400-013).
FOR 21WV1
843EZ (Ref. TASK 25-23-47-400-013).
FOR 21WV2
844EZ (Ref. TASK 25-23-47-400-013). Subtask 52-71-00-410-069
B. Close Access
(1)
Obey the special precautions after the work on the emergency exit (Ref. TASK 52-22-00-860-004).
(2)
Make sure that the work area is clean and clear of tool(s) and other items.
(3)
Close the applicable emergency exit 833 or 843 or 834 or 844 (Ref. TASK 52-22-00-410-002).
(4)
Remove the access platform(s).
1EFF : 301-399, 1 52-71-00Page 584 1 1 May 01/05R 1 1 1CES 1
Subtask 52-71-00-862-059
C. De-energize the ground service network (Ref. TASK 24-42-00-862-001)
1EFF : 301-399, 1 52-71-00Page 585 1 1 May 01/05R 1 1 1CES 1
TASK 52-71-00-820-007- 01
Adjustment of the Proximity Switches (19WV1, 19WV2, 21WV1,21WV2) of the Emergency Exits with the ECAM DU
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 3.20 m (10 ft. 6 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 19-010 USA AMS 5687 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 52-22-00-010-002 Opening of the Emergency Exit Doors from the Outside 52-22-00-410-002 Closing of the Emergency Exit Doors from the Outside 52-22-00-860-004 Special Precaution after Maintenance on the Door
Damper and Emergency Operation Cylinder 52-71-00-710-001 Operational Test of the Door Warning System 52-71-00-991-014 Fig. 512
1EFF : 301-399, 1 52-71-00Page 586 1 1 May 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
FOR FIN 19WV1
25-23-47-000-012 Removal of the Door Linings of the LH FWD Emergency
Exit Door, zone 231
25-23-47-400-012 Installation of the Door Linings of the LH FWD
Emergency Exit Door, zone 231
FOR FIN 19WV2
25-23-47-000-013 Removal of the Door Linings of the RH FWD Emergency
Exit Door at zone 251 or RH AFT at zone 252 or LH AFT
at zone 232.
25-23-47-400-013 Installation of the Door Linings of the RH FWD
Emergency Exit Door at zone 251, or RH AFT at zone
252, or LH AFT at zone 232.
FOR FIN 21WV1
25-23-47-000-013 Removal of the Door Linings of the RH FWD Emergency
Exit Door at zone 251 or RH AFT at zone 252 or LH AFT
at zone 232.
25-23-47-400-013 Installation of the Door Linings of the RH FWD
Emergency Exit Door at zone 251, or RH AFT at zone
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(19)