R No specific Torque Wrench : range 0.00 to 1.20 m.daN
R (0.00 to 9.00 lbf.ft) 355M03210000 1 CHECKING TOOL-DOORS
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
Material No. 19-010 USA AMS 5687
LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
(Ref. 20-31-00)
1EFF : ALL 1 52-71-00Page 592 1 1 May 01/05 1 1 1CES 1
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from
the External Power 52-41-00-010-002 Open the Avionics Compartment Doors for Access 52-41-00-410-002 Close the Avionics Compartment Doors after Access 52-71-00-710-001 Operational Test of the Door Warning System 52-71-00-991-015 Fig. 513
3. Job Set-up
__________
Subtask 52-71-00-861-062
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
Subtask 52-71-00-010-075
B. Get Access
(1)
Put an access platform in position in front of the applicable avionics compartment door.
(2)
Open the applicable avionics compartment door 811 or 812 or 824 (Ref. TASK 52-41-00-010-002).
(3)
Get access to the avionics compartment.
(4)
Close the applicable avionics compartment door 811 or
812 or
824 (Ref. TASK 52-41-00-410-002).
Subtask 52-71-00-865-063
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU EIS/SDAC1 AND 2/DOOR/DET/AVNCS 46WV P02
1EFF : ALL 1 52-71-00Page 593 1 1 May 01/05R 1 1 1CES 1
4. Procedure
_________ Subtask 52-71-00-820-071
A. Adjustment of the Proximity Switch
(Ref. Fig. 513/TASK 52-71-00-991-015)
WARNING : DO NOT OPEN THE DOOR DURING THE ADJUSTMENT.
_______
(1)
Make sure that all the doors are closed.
(2)
Disconnect the electrical connector of the proximity switch
(3)
Put blanking caps on the disconnected electrical connectors.
(4)
Connect the CHECKING TOOL-DOORS (355M03210000) to the electrical connector of the proximity switch (3).
(5)
Cut the lockwire from the nut (1).
(6)
Loosen the nut (1) of the target (2).
(7)
Turn the target (2) until the NEAR indicator light comes on. NOTE : The target (2) and the proximity switch (3) must not be in
____
contact.
(8)
Turn the target (2) in the opposite direction until the FAR indicator light comes on.
(9)
From this position, screw the adjustable target by two turns to two turns and a half.
(10)
TORQUE the nut (1) to between 0.6 and 0.7 m.daN (53.09 and 61.94 lbf.in).
(11)
Safety the nut (1) with the MISCELLANEOUS (Material No. 19-010).
(12)
Disconnect the CHECKING TOOL-DOORS (355M03210000) from the proximity switch (3).
(13)
Remove the blanking caps from the electrical connectors.
(14)
Connect the electrical connector of the proximity switch (3) to its related connector.
1EFF : ALL 1 52-71-00Page 594 1 1 May 01/05R 1 1 1CES 1
Proximity Switches - Avionics Compartment Doors Figure 513/TASK 52-71-00-991-015
1EFF : 1 1R 1CES ALL 1 11 1 52-71-00 Page 595 May 01/05
Subtask 52-71-00-865-064
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 46WV
Subtask 52-71-00-710-063
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(21)