WARNING : DO NOT OPEN THE DOOR DURING THE ADJUSTMENT.
_______
(1) Make sure that the cargo door is correctly closed and locked with the locking handle in the recess of the handle flap.
1EFF : ALL 1 52-71-00Page 556 1 1 Feb 01/05R 1 1 1CES 1
Proximity Switches (30WV, 32WV) - Cargo Compartment Door Threshold Figure 507/TASK 52-71-00-991-007
1EFF : ALL 1 52-71-00Page 557 1 1 Feb 01/05R 1 1 1CES 1
(2)
Disconnect the electrical connector (21) from the target (23).
(3)
Put blanking caps on the disconnected electrical connectors.
(4)
Measure the clearance J1 between the target (31) and the related proximity sensor (23).
-The clearance J1 must be 1.75 -0.25 +0.25 mm (0.0688 -0.0098 +0.0098 in.).
(5)
If the clearance J1 is not in the tolerances adjust as follows:
(a)
Release the tabs of the tab washers (36) from the jam nuts (37).
(b)
Loosen the jam nuts (37) to disassemble the link assy (40).
(c)
Turn the connector rod (38) counterclockwise to remove it from the two fork ends (35), (39).
(d)
Remove and discard the tab washers (36) from the connection rod (38).
R (e) Install new tab washers (36) on the connection rod (38).
(f)
Put the connection rod (38) to between the lower (35) and the top fork end (39) and turn it clockwise to assemble the link assy (40).
(g)
Turn the connection rod (38) until the clearance between the sensor (23) and the target (31) is correct.
(h)
Examine the link assy (40) to make sure that the connection rod
(38) is installed correctly in the two fork ends (35), (39).
(i)
Tighten the jam nuts (37) and safety them with tab washers (36).
(6)
Remove the blanking caps from the electrical connectors.
(7)
Connect the electrical connector (21) of the proximity sensor (23).
(8)
Go out of the cargo compartment and close the applicable cargo compartment door.
Subtask 52-71-00-710-059
B. Operational Test
(1) Do an operational test of the door warning system related to the cargo doors (Ref. TASK 52-71-00-710-001).
1EFF : ALL 1 52-71-00Page 558 1 1 Feb 01/05 1 1 1CES 1
5. Close-up
________ Subtask 52-71-00-410-058
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access panel(s) 825AR and/or 826AR.
(3)
Remove the access platform(s).
(4)
Close the applicable cargo door 825 or 826 (Ref. TASK 52-30-00-860-002).
Subtask 52-71-00-865-053
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1MJ
Subtask 52-71-00-862-053
C. De-energize the aircraft electrical circuit (Ref. TASK 24-41-00-862-002).
1EFF : ALL 1 52-71-00Page 559 1 1 May 01/04R 1 1 1CES 1
TASK 52-71-00-820-004
Adjustment of the Proximity Switches 28WV and 34WV of the Locking Handle of the Cargo Compartment Doors
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking cap
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
52-31-21-000-002 Removal of the Handle Flap Mechanism
52-31-21-400-002 Installation of the Handle Flap Mechanism
52-71-00-710-001 Operational Test of the Door Warning System
R **ON A/C 001-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
52-71-00-991-008 Fig. 508
**ON A/C 051-052,
52-71-00-991-008-A Fig. 508A
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(13)