• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-27 00:08来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 25-23-47-400-012  Installation of the Door Linings of the LH FWD Emergency Exit Door, zone 231
 25-23-47-400-013  Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232.
 52-22-00-010-001  Opening of the Emergency Exit Doors from the Passenger Compartment
 1EFF : 301-399, 1 52-71-13Page 405 1 1 Config-2 May 01/04 1 1 1CES 1 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------


52-22-00-410-001 Closing of the Emergency Exit Doors from the Passenger Compartment 52-22-00-860-003 Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder 52-22-00-860-004 Special Precaution after Maintenance on the Door
 Damper and Emergency Operation Cylinder 52-71-00-710-001 Operational Test of the Door Warning System 52-71-13-991-002 Fig. 401
 3. Job Set-up
__________
 Subtask 52-71-13-860-052
 A. Aircraft Maintenance Configuration
 (1)
 Make sure that the special precaution of the door damper and emergency operation cylinder is completed (Ref. TASK 52-22-00-860-003).

 (2)
 Make sure that the access platform is in position below the partly opened emergency exit door (referred to as door) (Ref. TASK 52-22-00-010-001).

 (3)
 Make sure that the door lining is removed (Ref. TASK 25-23-47-000-012) or (Ref. TASK 25-23-47-000-013).


 Subtask 52-71-13-865-057
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11 121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
 1EFF : 301-399, 1 52-71-13Page 406 1 1 Config-2 May 01/04 1 1 1CES 1


 4. Procedure
_________ Subtask 52-71-13-420-051
 A. Installation of the Proximity Switch
 (Ref. Fig. 401/TASK 52-71-13-991-002)

 (1)
 Clean the component interface and/or the adjacent area.

 (2)
 Do an inspection of the component interface and/or the adjacent area.

 (3)
 Make sure that the electrical connectors are clean and in the correct condition.

 (4)
 Install the proximity sensor (2) as follow:

 (a)
 Put the proximity sensor (2) in position in the attachment bracket (3).

 (b)
 Install the lockwasher (4) and the locknut (5) at the proximity sensor (2).

 


 NOTE : Make sure that the lockwasher (4) is correctly engaged in
____ the related hole in the attachment bracket (3).
 (c)
 TORQUE the locknut (5) to max. to 3.0 m.daN (22.12 lbf.ft).

 (d)
 Safety the locknut (5) and the lockwasher (4) with lockwire, corrosion resistant steel, dia. 0.8 mm (0.032 in).

 (e)
 Remove the blanking caps from the electrical connectors.

 (f)
 Connect the connector (1) to the proximity sensor (2).


 (5) Install the target (6) as follows:
 (a)
 Install the target (6) at the shaft lever (9).

 (b)
 Install the lockwasher (7) and the nut (8) on the target (6). NOTE : Do not tighten the locknut (8) at this time.


____
 1EFF : 301-399, 1 52-71-13Page 407 1 1 Config-2 May 01/04 1 1 1CES 1 Subtask 52-71-13-820-051


 B. Adjustment of the Proximity Switch
 (1) Measure the clearance between the proximity sensor (2) and its related target (6).
 NOTE : The clearance must be between 1.6 mm (0.0629 in.) and 2.0 mm
____
 (0.0787 in.).

 (2) If necessary, adjust the target position as follows:
 (a)
 Turn the target (6) until the clearance between the proximity sensor (2) and the target (6) is correct.

 (b)
 When the clearance is correct, tighten the nut (8).

 (c)
 Safety the locknut (8) with lockwire, corrosion resistant steel, dia. 0.8 mm (0.032 in).


 Subtask 52-71-13-865-053
 C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 48WV, 13WN, 15WN
 Subtask 52-71-13-710-050
 D. Do an operational test to make sure that the proximity switch operates correctly (Ref. TASK 52-71-00-710-001).
 5. Close-up
________ Subtask 52-71-13-410-052
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(49)