(3)
Remove the switch actuation mechanism as follows:
(a)
Remove the safety ring (24), the washer (23) and the pin (20) to disconnect the connection rod (14) from the link (21).
(b)
Remove and discard the cotter pin (16) from the pin (18).
(c)
Remove the the pin (18) and the washer (17) to disconnect the segment assy (15) from the structure.
(d)
If necessary, disassemble the connection rod (14) from the segment assy (15).
1EFF : 301-399, 1 52-71-13Page 413 1 1 Config-2 May 01/04 1 1 1CES 1
TASK 52-71-13-400-003 Installation of the Proximity Switches 59WV1, 59WV2, 61WV1 and 61WV2
1. Reason for the Job
__________________
To replace the components of the applicable proximity switch and its
actuation mechanism.
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific Torque Wrench : range 0.20 to 3.60 m.daN
(2.00 to 26.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific lockwire, corrosion resistant steel, dia. 0.8 mm
(0.032 in) No specific lockwire, corrosion-resistance steel, dia. 0.8 mm
(0.30 in.)
C. Expendable Parts
-------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
cotter pin 52-22-04 08 -120
1EFF : 301-399, 1 52-71-13Page 414 1 1 Config-2 May 01/04 1 1 1CES 1
D. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
25-23-47-400-009 Installation of the Door Frame Linings of the RH FWD Emergency Exit Door, zone 232 25-23-47-400-010 Installation of the Door Frame Linings of the LH/RH AFT Emergency Exit Doors, zones 251/252. 52-22-00-410-001 Closing of the Emergency Exit Doors from the Passenger Compartment 52-22-00-860-004 Special Precaution after Maintenance on the Door
Damper and Emergency Operation Cylinder 52-71-00-710-001 Operational Test of the Door Warning System 52-71-13-991-003 Fig. 402
3. Job Set-up
__________
Subtask 52-71-13-865-058
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11 121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
4. Procedure
_________
Subtask 52-71-13-420-052
A. Installation of Proximity Switches 59WV1, 59WV2, 61WV1 and 61WV2
(Ref. Fig. 402/TASK 52-71-13-991-003)
(1)
Make sure that the parts retained from the removed component are clean and in the correct condition.
(2)
Clean the component interface and/or the adjacent area.
(3)
Do an inspection of the component interface and/or the adjacent area.
1EFF : 301-399, 1 52-71-13Page 415 1 1 Config-2 May 01/04 1 1 1CES 1
(4)
Install the switch actuation mechanism as follows:
(a)
If necssary, assemble the connection rod (14) to the segment assy (15).
(b)
Put the segment assy (15) in position at the fuselage structure.
(c)
Install the pin (18) and the washer (17) to attach the segment assy (15).
(d)
Safety the pin (18) with a new cotter pin (16).
(e)
Put the eye-end of the connection rod (14) in position at the link (21) and attach it with the washer (23) and the pin (20).
(f)
Safety the pin (20) with the safety ring (24).
(5)
Install the switch bracket (3) as follows:
(a)
Put the switch bracket (3) in position and attach it with the screws (8), the washers (11) and the nuts (12).
(b)
Put the link (21) in position at the switch bracket (3).
(c)
Install the pin (19) and the washer (6) to connect the link (21) with the switch bracket (3).