(2)
Open the applicable FWD passenger/crew door 831 or 841 (Ref. TASK 52-10-00-010-001).
Subtask 52-73-11-865-059
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11 121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
Subtask 52-73-11-420-061
D. Disarming of the Escape Slide of the Emergency Exits
(Ref. Fig. 405/TASK 52-73-11-991-004)
(1) Disarm the escape slide of the emergency exit (10) as follows:
(a)
Open and remove the flaps (8). NOTE : The white SLIDE ARMED indicator-light (11) comes on.
____
(b)
Turn the head of the latch pin (9) with a wrench a quarter turn counterclockwise to retract the latch pin (9).
NOTE : The white SLIDE ARMED indicator light (11) goes off.
____
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-73-11Page 434 1 1 May 01/05 1 1 1CES 1
Proximity Switches (6WN1 ,6WN2) of the Aft Emergency Exits
Figure 405/TASK 52-73-11-991-004
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-73-11Page 435 1 1 May 01/05 1 1 1CES 1 Subtask 52-73-11-010-062
E. Removal of the Lining Panel
(1)
Disconnect the electrical connector from the SLIDE ARMED indicator-light.
(2)
Put blanking caps on the disconnected electrical connectors.
(3)
Remove the lining panel:
FOR 6WN1
241LW (Ref. TASK 25-23-47-000-002).
FOR 6WN2
242LW (Ref. TASK 25-23-47-000-002).
(4)
Remove the insulation blanket.
(5)
Remove the air outlet (7).
4. Procedure
_________ Subtask 52-73-11-020-053
A. Removal of the Proximity Switch
(Ref. Fig. 405/TASK 52-73-11-991-004)
(1)
Disconnect the electrical connector (1) from the proximity switch (2).
(2)
Put blanking caps on the disconnected electrical connectors.
(3)
Remove and discard the lockwire.
(4)
Remove the nut (5) and the washer (4).
(5)
Remove the proximity switch (2).
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-73-11Page 436 1 1 May 01/05 1 1 1CES 1R **ON A/C 301-399,
R TASK 52-73-11-000-004-B R Removal of the Proximity Switches (6WN1, 6WN2) of the Aft Emergency Exits R 1. Reason for the Job
__________________ R Self Explanatory R 2. Job Set-up Information
______________________
R A. Fixtures, Tools, Test and Support Equipment
R -------------------------------------------------------------------------------R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------
R No specific blanking caps
R No specific circuit breaker(s) safety clip(s)
R No specific access platform 3.5 m (11 ft. 6 in.)
R B. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R 24-42-00-861-001 R R 52-22-00-010-002 R 52-22-00-860-003 R R 52-73-11-991-007 R FOR FIN 6WN1 R 25-23-47-000-013 R R R FOR FIN 6WN2 R 25-23-47-000-013 R R Energize the Ground Service Network from the External Power Opening of the Emergency Exit Doors from the Outside Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder Fig. 406
Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232.
Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232.
R 1EFF : 301-399, 1 52-73-11Page 437 1 1 May 01/04 1 1 1CES 1
R 3. Job Set-up__________
R Subtask 52-73-11-861-057
R A. Energize the ground service network
R (Ref. TASK 24-42-00-861-001).
R Subtask 52-73-11-865-068
R B. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11