-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
2. Disconnect the shunt CONNECTOR On all the passenger/crew doors and SHUNT (98D52703000000) from the emergency exits: connector of the pressure switch - the red CABIN PRESSURE warning light (14WN). panel goes off.
**ON A/C ALL
5. Close-up
________
Subtask 52-73-00-420-053
A. Installation of Components
WARNING : DO NOT OPEN THE RADOME IF THE WIND SPEED IS MORE THAN 35 KNOTS.
_______
(1) Connect the connector of the cabin pressure detection pressure switch (14 WN) (Ref. TASK 52-73-12-400-001).
Subtask 52-73-00-865-062
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU LIGHTING/EMER LT/CABIN 2WL H06 49VU LIGHTING/EMER LT/CABIN 1WL H05 122VU LIGHTING/CABIN/EMER/LT 3WL V07
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Subtask 52-73-00-410-051
C. Close Access
(1)
Obey the special precautions after the work on the door (Ref. TASK 52-10-00-860-002).
(2)
Make sure that the applicable passenger/crew door is closed (Ref. TASK 52-10-00-410-001).
1EFF : ALL 1 52-73-00Page 537 1 1 Aug 01/05 1 1 1CES 1 1EFF : ALL 1 52-73-00Page 538 1 1 May 01/04 1 1 1CES 1 PROXIMITY SWITCH (4WN1,4WN2,5WN1,5WN2,6WN1,6WN2,7WN1,7WN2)
(3) Remove the access platform(s).
R **ON A/C 301-399,
R Subtask 52-73-00-410-051-A
R C. Close Access
R (1) Obey the special precautions after the work on the door or emergency
R exit (Ref. TASK 52-10-00-860-001) (Ref. TASK 52-22-00-860-004).
R (2) Make sure that the applicable passenger/crew door or emergency exit
R is closed (Ref. TASK 52-10-00-410-001) (Ref. TASK 52-22-00-410-002).
R (3) Remove the access platform(s).
R **ON A/C ALL
Subtask 52-73-00-862-054
D. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
__________________________________________________________ REMOVAL/INSTALLATION
____________________
TASK 52-73-11-000-001
Removal of the Proximity Switches (4WN1, 4WN2) of the FWD Passenger/Crew Doors
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
No specific access platform 3.5 m (11 ft. 6 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
Power 52-10-00-010-001 Opening of the Passenger/Crew Door 52-10-00-860-001 Special Precautions before Work on the Passenger/Crew
Door 52-73-11-991-001 Fig. 401 FOR FIN 4WN1 25-23-46-000-001 Removal of the Door Linings at the FWD Passenger/Crew
Doors FOR FIN 4WN2 25-23-46-000-001 Removal of the Door Linings at the FWD Passenger/Crew
Doors
1EFF : ALL 1 52-73-11Page 401 1 1 Feb 01/98 1 1 1CES 1
3. Job Set-up
__________
Subtask 52-73-11-861-052
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
Subtask 52-73-11-010-050
B. Get Access
WARNING : DO NOT OPEN THE PASSENGER/CREW DOOR IF THE WIND SPEED IS MORE
_______
THAN 65 KNOTS.
WARNING : BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
_______
-
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门8(68)