 S 432-055
 CAUTION:_______MAKE SURE YOU INSTALL THE CONDUIT CORRECTLY. INCORRECT INSTALLATION WILL CAUSE DAMAGE TO THE CONDUIT.
 (3)  
Install the conduit:

 (a)  
Install the clamps between the sections that have tape.

 (b)  
Make sure that the upper mounting bolt for the anchor bracket is 3.6 inches from the vertical link attach point.


 S 432-042
 (4)  
Connect the sensor wires:

 (a)  
Cut the sensor wires to the correct length and install the terminal lugs (7) on the sensor wires.

 (b)  
Install the terminal lug (7) on the terminal strip.

 (c)  
Install the washers (9), the lock washers (10), and the nuts (11).


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 32-61-03
 ALL  ú ú 01 Page 207 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 S 722-069
 (5)  Do the test of the sensors with the actuator test tool (Refer to the task to do a Test of the Nose Gear Lock Sensor.
 NOTE: Make sure the sensor is kept more than one inch away from
____
 any metal surface during the test.

 S 422-068
 CAUTION:_______DO NOT DROP OR HIT THE SENSORS. YOU CAN CAUSE DAMAGE TO THE INTERNAL COMPONENTS OF THE SENSORS AND CAUSE A FAILURE OF THE INDICATION SYSTEM.
 (6)  
Install the sensor:

 (a)  
Hold the sensor (2) in its position on the bracket (4).

 (b)  
Make sure that the clearance between the sensor and the target is as shown on Fig. 201. 1) If the clearance is not correct, adjust the sensor (Refer

 to the task for the Nose Gear Lock Sensor Adjustment).

 (c)  
Install the sensor (2) with the screws (1), washers (5), and nuts (6).


 S 392-043
 CAUTION:_______MAKE SURE YOU SEAL THE ELECTRICAL TERMINALS. IF YOU DO NOT SEAL THE ELECTRICAL TERMINALS, CONTAMINATION CAN GET INTO THEM AND CAUSE DAMAGE TO THE SENSORS.
 (7)  
Seal the electrical terminals:

 (a)  
Clean the bare surface of the terminals with solvent.

 (b)  
Apply a thin layer of primer on the bare surface of the terminals and let it dry.

 (c)  
Apply sealant on the surface of the terminals with a short bristle brush.


 S 862-024
 (8)  
Remove the DO-NOT-CLOSE tag and close the applicable circuit breaker on the P7 Overhead Circuit Breaker Panel:

 (a)  
7F23, LANDING GEAR DSP & CONT ALTN

 (b)  
7F22, LANDING GEAR DSP & CONT PRI

 (9)  
Put the airplane back to the ground mode (AMM 32-09-02/201).

 S 742-027

 (10)
 Do the ground test of the PSEU Landing Gear Systems (AMM 32-61-00/501).


 S 442-044
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 32-61-03
 ALL  ú ú 01 Page 208 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 092-045
 WARNING:_______OBEY THE REMOVAL PROCEDURE FOR THE DOOR LOCKS. THE DOORS OPEN AND CLOSE QUICKLY. THE MOVEMENT OF THE DOORS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
 (11) Remove the door lock for the nose gear (AMM 32-00-30/201).
 TASK 32-61-03-722-056
 4.  Test of the Nose Gear Lock Sensor_________________________________
 A. General
 (1)  
This test makes sure the nose gear lock sensors operate correctly.

 (2)  
Do this test with the landing gear in the down and
 locked position.


 B.
References

 (1)  
AMM 24-22-00/201, Electrical Power

 (2)  
AMM 32-00-30/201, Landing Gear Door Locks

 C.
Equipment

 (1)  
A27092-84 - Proximity Sensors Actuator/Deactuator Set (Recommended)


 A32102-25 - Proximity Sensors Actuator/Deactuator Set
 (Alternative)
 A32102-1 - Proximity Sensors Actuator/Deactuator Set
 