• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-13 07:53来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

A27092-84 Actuator/Deactuator Set - Proximity Sensors

 B.  
Consumable Materials

 (1)  
A00704 Sealant - Silicone, RTV 162

 (2)  
B00083 Solvent - Aliphatic Naphtha, TT-N-95, Type 2

 (3)  
C00582 Primer - SS-4004

 C.  
References

 (1)  
24-22-00/201, Manual Control

 (2)  
29-11-00/201, Main Hydraulic Supply System

 (3)  
32-00-30/201, Landing Gear Door Locks

 (4)  
32-09-02/201, Air/Ground Relay System

 (5)  
IPC 32-61-08 Fig. 2

 D.  
Access

 (1)  
Location Zone 135 Wing Gear Wheel Well, LH (Forward Bulkhead) 136 Wing Gear Wheel Well, RH (Forward Bulkhead)

 E.  
Install the Door Warning Sensor (Fig. 201)


 S 422-012
 (1)  
Install the sensor:

 (a)  
Twist the sensor wires.

 (b)  
Attach the line that you kept in the conduit (during the removal), to the end of the sensor wires.

 (c)  
Carefully pull the wires through the conduit.

 (d)  
Install the sensor with the mounting screws.


 NOTE: A correctly installed sensor will give you the clearance
____ shown on Fig. 201. The clearance adjustment is usually not necessary. A check of the clearance must be done if the sensor mounting support is moved, if the door is replaced, or the doorstop is adjusted.
 1)  Make sure you install the head of the screw on the sensor side.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 32-61-32
 ALL  ú ú 01 Page 204 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 2) Do the steps for the sensor adjustment if it is necessary.
 S 432-030
 (2)  
Connect the sensor wires:

 (a)  
Cut the sensor wires to the correct length and install the terminal lugs.

 (b)  
Connect the sensor wires to the terminal strip.
 1) Make sure the terminals are connected correctly.

 

 NOTE: Use the colors of the wires.
____
 CAUTION: IF YOU DO NOT SEAL THE ELECTRICAL TERMINALS CORRECTLY, YOU
_______ CAN HAVE SHORTED OR BURNED OUT SWITCHES CAUSED BY THE UNWANTED MATERIALS THAT GO INTO THE JUNCTION BOXES.
 (c)  Seal the electrical terminals: 1) Clean the bare surface of the terminals with the solvent. 2) Apply a thin layer of the primer on the bare surfaces of
 the terminals. a) Let the primer dry. 3) Apply the sealant on the terminals with a short-bristle brush.
 S 412-013
 (3)  Install the cover on the junction box (J22 LH, J25 RH).
 S 092-014
 WARNING: YOU MUST CAREFULLY DO THE STEPS IN THE TASK BELOW TO REMOVE THE
_______ DOOR LOCKS FROM THE LANDING GEAR DOORS. THE DOORS CAN CLOSE QUICKLY IF YOU DO NOT REMOVE THE DOOR LOCKS CORRECTLY. THIS CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
 (4)  Do this task: "Removal of the Door Locks on the Wing Landing Gear" (Ref 32-00-30/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 32-61-32
 ALL  ú ú 01 Page 205 ú Oct 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 092-031
 (5)  
Do this task: "Removal of the Door Locks on the Body Landing Gear" (Ref 32-00-30/201).

 S 862-015

 (6)  
Remove the pressure in the No. 1 and 4 hydraulic systems
 (Ref 29-11-00/201).


 F.
Adjustment of the Door Warning Sensor (if it is necessary)


 NOTE: A correctly installed sensor will give you the clearance shown on
____ Fig. 201. The clearance adjustment is usually not necessary. A check of the clearance must be done if the sensor mounting support is moved, if the door is replaced, or the doorstop is adjusted.
 S 822-019
 (1)  
Adjust the door warning sensor:

 (a)  
Make sure the clearance between the sensor and the target is in the limits shown on Fig. 201.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 起落架 LANDING GEAR 9(119)