(b)
Examine the electrical connector for bent or broken pins, dirt, and damage.
(c)
Connect the electrical connector on the rear of the control panel.
(d)
Set the VHF communication control panel in its position on the P8 panel.
(e)
Tighten the four quarter-turn fasteners on the front of the control panel.
S 864-012
(2) Remove the DO-NOT-CLOSE tags and close the circuit breaker for the VHF panel that you installed:
(a)
P6-1 Circuit Breaker Panel:
1) VHF-2
2) ELEX PANEL
(b)
P18-2 Circuit Breaker Panel:
1) VHF-1
2) VHF-3 (if installed)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
23-21-31
ALL ú ú 02 Page 402 ú Mar 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 864-023
(3) Make sure that the circuit breakers for the other panels are open.
NOTE: You will close one circuit breaker at a time to do a check
____
for a cross-connection.
D. VHF Communication Control Panel Installation Test
S 864-013
(1)
Supply electrical power (AMM 24-22-00/201).
S 714-014
(2)
Use the new VHF communication control panel to set the applicable VHF communication system to a test frequency.
(a) Make sure the transmission and reception are satisfactory.
S 864-024
(3) Remove the DO-NOT-CLOSE tag and close the circuit breakers for one of the other VHF communication control panels:
(a)
P6-1 Circuit Breaker Panel:
1) VHF-2
2) ELEX PANEL
(b)
P18-2 Circuit Breaker Panel:
1) VHF-1
2) VHF-3 (if installed)
S 714-025
(4) Use the applicable VHF communication control panel to set the VHF communication system to a test frequency.
(a) Make sure the transmission and reception are satisfactory.
S 864-026
(5) Remove the DO-NOT-CLOSE tag and close the last circuit breaker for VHF communication control panels:
(a) P6-1 Circuit Breaker Panel:
1) VHF-2
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
23-21-31
ALL ú ú 02 Page 403 ú Mar 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(b) 2) ELEX PANELP18-2 Circuit Breaker Panel: 1) VHF-1 2) VHF-3 (if installed)
(6) S 714-027Use the applicable VHF communication control panel to set the VHF communication system to a test frequency. (a) Make sure the transmission and reception are satisfactory.
(7) S 864-015Remove electrical power if it is no longer necessary (AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
23-21-31
ALL ú ú 01 Page 404 ú Mar 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
1.
2.
3.
A
737-300/400/500MAINTENANCE MANUAL
AIRCRAFT COMMUNICATIONS ADDRESSING AND REPORTING SYSTEM (ACARS) -
_________________________________________________________________ DESCRIPTION AND OPERATION
_________________________
General
_______
A. The Aircraft Communications Addressing and Reporting System (ACARS) transmits and receives digital messages in conjunction with a ground station. Messages are transmitted by use of the VHF-3 transceiver. By automatically transmitting such data as departure station, destination, estimated time of arrival, crew payroll numbers, fuel, APU data and flight number, the crew workload is lessened. The ACARS system consists of management unit (MU) and control unit (CU).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 通讯 COMMUNICATIONS(31)