• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-02-24 09:55来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 

R **ON A/C 001-003, 051-054,
 TASK 21-61-00-040-003
 Deactivation of the Air Outlet Flap in the Open Position
 1. Reason for the Job
__________________
 Refer to the MMEL TASK: 21-52-03 a)
 Air cooling system
 Air outlet flap

 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific circuit breaker(s) safety clip(s)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
21-61-00-710-001 Operational Test of the Pack Temperature-Control
 System 21-61-52-000-002 Removal of the Ram-Air Outlet Flap 21-61-52-200-001 Detailed Inspection of the Ram Air Outlet Flap and
 Check for Excessive Backlash of Outlet Flap 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 53-35-13-000-002 Removal of the Quick-Release Access Panels from the Belly Fairing Structure 53-35-13-400-002 Installation of the Quick-Release Access Panels on
 the Belly Fairing Structure
 21-61-00-991-002 Fig. 402
 21-61-00-991-008 Fig. 403

R 1EFF : 001-003, 051-054, 1 21-61-00Page 412 1 1 May 01/05 1 1 1CES 1


 3. Job Set-up
__________
 Subtask 21-61-00-861-055
 A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
 Subtask 21-61-00-865-056
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 9HH
 122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 1HH X22 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC 3HH X21 122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC 4HH Y19 122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC 2HH Y18
 FOR 29HH 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 21HH W22 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 23HH W21 122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 24HH Y21 122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC 22HH Y20
 Subtask 21-61-00-010-054
 C. Get Access
 (1) Remove the access panel/s (Ref. TASK 53-35-13-000-002).
R (a) FOR 9HH
 -191KB,
R (b) FOR 29HH
 -192KB.
R 1EFF : 001-003, 051-054, 1 21-61-00Page 413 1 1 May 01/05 1 1 1CES 1


 4. Procedure
_________
 (Ref. Fig. 402/TASK 21-61-00-991-002) Subtask 21-61-00-210-054
 A. Inspect the ram-air outlet flap for backlash (Ref. TASK 21-61-52-200-001).
 (1) If the backlash is more than 20 mm (0.7874 in.) you must:
 (a)
 Remove the air outlet flap (Ref. TASK 21-61-52-000-002).

 (b)
 Temporarily secure the air-outlet flap actuator and the disconnected electrical connector to the aircaft structure.

 (c)
 Retain the removed components and the air outlet flap. NOTE : These must remain with the aircraft until you do the


____ reactivation of the air outlet flap.
 Subtask 21-61-00-210-055
 B. Check of the Air-Outlet Flap Gap NOTE : This work step is not necessary if the air outlet flap has been
____
 removed.

 (1) Do a check of the air-outlet flap gap with hand load pressure applied (dimension A). (Ref. Fig. 403/TASK 21-61-00-991-008)
 (a)
 If the air-outlet flap gap is more than 40 mm (1.5748 in.) do the work steps in paras:

 -4. E, F, G, and H and,
 -5. A and B.

 (b)
 If the air-outlet flap gap is less than 40 mm (1.5748 in.) carry on with the deactivation task.


R 1EFF : 001-003, 051-054, 1 21-61-00Page 414 1 1 May 01/05 1 1 1CES 1


 Air Outlet Flap - Component Location
 Figure 402/TASK 21-61-00-991-002

R 1EFF : 001-003, 051-054, 1 21-61-00Page 415 1 1 May 01/05 1 1 1CES 1


 Air-Outlet Flap Gap - Dimension check
 Figure 403/TASK 21-61-00-991-008

R 1EFF : 001-003, 051-054, 1 21-61-00Page 416 1 1 May 01/05 1 1 1CES 1 Subtask 21-61-00-210-052


 C. Inspection of the Air Outlet Flap before Deactivation NOTE : This work step is not necessary if the air outlet flap has been
____
 removed.

 NOTE : The work steps which follow are necessary to ensure that when you
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 5(9)