Subtask 21-61-51-865-067 
 B. Open, safety and tag this(these) circuit breaker(s): 
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 8HH  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
R  122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC  1HH 3HH  X22X21  
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,  
R R  122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,  4HH  Y19  
R R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC **ON A/C 106-149, 303-399,  2HH  Y18  
R  122VU  4HH  Y19 
 **ON A/C ALL 
 FOR 28HH  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC  21HH 23HH 24HH 22HH  W22W21Y21Y20
 **ON A/C ALL
 Subtask 21-61-51-941-056
 C. Safety Precautions
 (1)
 On the panel 30VU:
 (a)
 Make sure that the APU BLEED and the ENG BLEED/1(2) pushbutton switches are released.
 (b)
 Put a warning notice in position to tell persons not to operate these pushbutton switches.
 (2)
 On the HP ground connector put a warning notice in position to tell persons not to supply the ground air.
 4. Procedure
_________
 (Ref. Fig. 601/TASK 21-61-51-991-009) Subtask 21-61-51-220-051
 A. Measurement of the Air Inlet Flap Backlash
 (1) At the centre line of the air inlet flap (1) and the diffuser nose (2):
 (a)
 Measure and note the dimension "A".
 (b)
 Measure and note the dimension "B". NOTE : The measurement for the dimension "B" must be made with
____ the load applied (hand pressure). Do not apply excessive hand pressure as this could result in a false measurement.
 (2)
 Subtract dimension "A" from dimension "B". This will give you the backlash which exists in the air-inlet flap system.
 (3)
 If the backlash is more than 3mm (0.118 in) you must do a check of the in-service wear limits of the air-inlet flap mechanism (Ref. TASK 21-61-51-000-003) and (Ref. TASK 21-61-51-200-003).
 (4)
 If necessary replace the affected parts (Ref. TASK 21-61-51-400-003) and (Ref. TASK 21-61-00-300-001).
 1EFF : ALL 1 21-61-51Page 609 1 1 Aug 01/05R 1 1 1CES 1
 (5) Make sure that the work area is clean and clear of tool(s) and other items. ________
5. Close-up
 Subtask 21-61-51-865-068
 A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
 (1)
 FOR 8HH
-1HH, 2HH, 3HH, 4HH.
 (2)
 FOR 28HH
 -
21HH, 22HH, 23HH, 24HH. Subtask 21-61-51-410-058
 B.
 Remove the warning notice(s). Subtask 21-61-51-862-056
 C. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
 1EFF : ALL 1 21-61-51Page 610 1 1 Aug 01/05R 1 1 1CES 1
 