R TSM 21-61-00-810-888 MCDU - NO TEST Indications
3. Job Set-up
__________
Subtask 21-61-00-861-059
A. Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
Subtask 21-61-00-865-052
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
R **ON A/C 401-499,
49VU AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC 52HH D08
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R R 122VU AIR COND/AFT CARGO VENT/FAN 122VU AIR COND/ZONE TEMP CTL/28VDC/SYS2 122VU AIR COND/ZONE TEMP CTL/28VDC/SYS1 122VU AIR COND/ZONE TEMP CTL/115VAC/SYS2 122VU AIR COND/ZONE TEMP CTL/115VAC/SYS1 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC 30HN 4HK 3HK 2HK 1HK 21HH 23HH 1HH 3HH 24HH 22HH S22V20V19V18V17W22W21X22X21Y21Y20
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
R 122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC 4HH Y19
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC 2HH Y18
R **ON A/C 106-149, 303-399,
R 122VU 4HH Y19
R -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------**ON A/C 401-499,
R R R R R R R 122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC 53HH 55HH 49HH 51HH 56HH 54HH 50HH W22 W21 X22 X21 Y21 Y20Y18
**ON A/C ALL
Subtask 21-61-00-865-069
C. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION FIN LOCATION -------------------------------------------------------------------------------122VU AIR COND/AFT CARGO VENT/CTL AND/MONG 31HN 20 S or alternative location :-49VU AIR COND/AFT CARGO/VENT/CTL & MONG 31HN 07 C
Subtask 21-61-00-860-051
D. Aircraft Maintenance Configuration
(1) Do the EIS start procedure (Ref. TASK 31-60-00-860-001).
(2) Make sure that on the ECAM BLEED page both of the pack flow-control valve symbols show closed.
NOTE : The test is only available if both pack flow-control symbols____ show closed on the BLEED page.
(3) On the AIR COND panel 30VU, make sure that: - the HOT AIR pushbutton switch is in the on position (the OFF and FAULT legends are off). - the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on).
(4)
On the CARGO HEAT panel 22VU, make sure that the HOT AIR pushbutton switch is in the on position (the OFF and FAULT legends are off).
(5)
On one MCDU get the SYSTEM REPORT/TEST AIR COND menu page (Ref. TASK 31-32-00-860-002).
4. Procedure
_________
**ON A/C 001-003, 051-054,
Subtask 21-61-00-710-050
A. Operational Test of the Pack Temperature-Control System
WARNING : MAKE SURE THAT THERE ARE NO PERSONS OR EQUIPMENT NEAR THE RAM
_______ AIR OUTLET FLAPS. THE MOVEMENT OF THE RAM AIR OUTLET FLAPS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 5(12)