FAN ELEC OR MECH FAIL
ACTUATOR MOTORACTUATOR POT 1
ACTUATOR POT 2ELEC OR MECH FAIL
VALVE MOTOR VALVE POT 1
VALVE POT 2 VALVE LIMIT SWITCH ELEC OR MECH FAIL
TRIM VALVE ELEC OR MECH FAIL
TRIM VALVE MOTOR
TRIM VALVE POT 1TRIM VALVE POT 2
VALVE SOLENOID REDUCEVALVE DISAGREE FAILED CLOSED
R 1EFF : 401-499, 1 21-61-00Page A26 1 1 Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------| BITE TEST |-----------------------------------------------------------------------------| | INDICATION ON THE MCDU | ATA REF. | BITE DETECTION | -------------------------------------------------------------------------------
TEMP SENSOR FWD CAB(22HK)  21-63-17 
 TEMP SENSOR AFT CAB(23HK)  21-63-17 
 TEMP SENSOR CKPT DUCT  21-63-15 
 (15HK) 
 TEMP SENSOR FWD CAB DUCT  21-63-15 
 (16HK) 
 TEMP SENSOR AFT CAB DUCT  21-63-15 
 (17HK)
TEMP SENSOR FWD DUCT(16HK) 21-63-15
 + AFT CABIN DUCT(17HK) 
 TEMP SENSOR L/H MIXER  21-63-16 
 (24HK) 
 TEMP SENSOR R/H MIXER  21-63-16 
 (25HK) 
 CKPT TEMP SELECTOR(27HK)  21-63-11 
 FWD CAB TEMP SELECTOR  21-63-11 
 (28HK) 
 AFT CAB TEMP SELECTOR  21-63-11 
 (29HK) 
 FLOW SELECTOR (5HB) 
 WAI:NO BLEED AIR ENG 1  30-11-00 
 WAI:NO BLEED AIR ENG 2  30-11-00 
 L WAI VALVE (9DL)  30-11-51 
 R WAI VALVE (10DL)  30-11-51 
R 1EFF : 401-499, 1 21-61-00Page A27 1 1 Aug 01/05 1 1 1CES 1 (3) Class 2 Maintenance Messages
 -------------------------------------------------------------------------------| BITE TEST |-----------------------------------------------------------------------------| | INDICATION ON THE MCDU | ATA REF. | BITE DETECTION | -------------------------------------------------------------------------------
BMC1 (1HA1)+BMC2 (1HA2)  36-11-34 
 CPC1 (11HL)+CPC2 (12HL)  21-31-34 
 CFDIU (1TW)  31-32-34 
 CIDS1 (101RH)  23-73-34 
 CIDS2 (102RH)  23-73-34 
 P1 FLOW CONT VALVE(23HB)  21-51-51  PNEUMATIC MODE FAULT 
 P2 FLOW CONT VALVE(24HB)  21-51-51  PNEUMATIC MODE FAULT 
 P1 OUT TEMP SENSOR(13HH)  21-53-18 
 P2 OUT TEMP SENSOR(34HH)  21-53-18 
 P1 PRESS INL SENS(23HB1)  21-61-16  SENSOR OUT OF RANGE 
 P2 PRESS INL SENS(24HB1)  21-61-16  SENSOR OUT OF RANGE 
 P1 DISCHARGE PRESS SENSOR  21-61-16  SENSOR OUT OF RANGE 
 (14HH) 
 P2 DISCHARGE PRESS SENSOR  21-61-16  SENSOR OUT OF RANGE 
 (20HH) 
 TEMP SENSOR CKPT(21HK)  21-63-17  SENSOR 1 OR 2 OUT OF RANGE 
 TEMP SENSOR FWD CAB(22HK)  21-63-17  SENSOR 1 OR 2 OUT OF RANGE 
 TEMP SENSOR AFT CAB(23HK)  21-63-17  SENSOR 1 OR 2 OUT OF RANGE 
 TEMP SENSOR CKPT DUCT  21-63-15  SENSOR 1 OR 2 OUT OF RANGE 
 (15HK) 
 TEMP SENSOR FWD CABIN  21-63-15  SENSOR 1 OR 2 OUT OF RANGE 
 DUCT (16HK) 
R 1EFF : 401-499, 1 21-61-00Page A28 1 1 Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------| BITE TEST |-----------------------------------------------------------------------------| | INDICATION ON THE MCDU | ATA REF. | BITE DETECTION | -------------------------------------------------------------------------------
TEMP SENSOR AFT CABIN  21-63-15  
DUCT (17HK) 
 CKPT TEMP SELECTOR(27HK)  21-63-11  
FWD CAB TEMP SELECTOR  21-63-11  
(28HK) 
 AFT CAB TEMP SELECTOR  21-63-11  
(29HK) 
 FLOW SELECTOR(5HB)  21-63-00  
ACSC1(47HH)  21-61-00 
 ACSC1(47HH)/ACSC2(57HH)/  21-61-00  
WRG: ACSC2 BUSSES TO 
 ACSC1 LANE1/2 
 CPC1(11HL)+CPC2(12HL)  21-31-34 
 RECIR FAN 1 OR SPLY(15HG)  21-21-51 
 MIXER FLAP ACTUATOR(20HB)  21-51-52
TRIM AIR PRESS VALVE(14HK) 21-63-52 OR PRESS SWITCH (26HK) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 5(5)