 FOR 29HH 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 21HH W22 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 23HH W21 122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 24HH Y21 122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC 22HH Y20
 Subtask 21-61-00-941-051
 C. Safety Precautions
 (1)
 On the AIR COND panel 30VU:

 (a)
 Make sure that the APU BLEED, the ENG BLEED/1(2) and the PACK/1(2) pushbutton switches are in the off position: - on the APU BLEED pushbutton switch the ON legend is off, - on the ENG BLEED/1(2) and the PACK/1(2) pushbutton switches the

 OFF legends are on.

 (b)
 Put a warning notice in position to tell persons not to operate these pushbutton switches.

 

 (2)
 Put a warning notice on the HP ground connector to tell persons not to supply the ground air.


 Subtask 21-61-00-010-059
 D. Get Access
 (Ref. Fig. 802/TASK 21-61-00-991-007)

 (1) Remove the access panel/s (Ref. TASK 53-35-13-000-002).
R (a) FOR 9HH
 -191KB
R 1EFF : 001-003, 051-054, 1 21-61-00Page 806 1 1 May 01/05 1 1 1CES 1


 Ram Air Outlet-Flap - Rivets and Attachment Components
 Figure 802/TASK 21-61-00-991-007

R 1EFF : 001-003, 051-054, 1 21-61-00Page 807 1 1 May 01/05 1 1 1CES 1R (b) FOR 29HH


 -192KB
 (2) Remove the nut (6), the bolt (3), the spacer (4) and disconnect the lever (5) from the actuator (2).
 NOTE : Hold the ram air outlet-flap (1) and the actuator (2) when you
____
 remove the bolt (3).

 (3) Let the ram air outlet-flap (1) move to the fully open position.
 4. Procedure
_________
 Subtask 21-61-00-350-055

 A. Replacement of Sheared or Loose Rivets
 (1)
 Remove or drill out the sheared or loose rivets.

 (2)
 If necessary increase the diameter of the rivet holes to a maximum of


 4.1 mm (0.1614 in.).
 NOTE : If the diameter of the rivet holes is larger than 4.1 mm

____ (0.1614 in.) then you must replace the ram air outlet-flap (Ref. TASK 21-61-52-000-002) and (Ref. TASK 21-61-52-400-002).
 (3)
 Countersink drill the holes to the correct size for the replacement rivets.

 (4)
 Clean the component and the adjacent area.

 (5)
 Install the rivets:

 (a)
 For the rivets (7),

 -Part Number NAS1921C05S03.

 (b)
 For the rivets (8) (where installed):

 -Part Number NAS 1921C05S02.

 (c)
 For the rivets (9):

 -Part Number DIN 65339-4000DF, select length from 8 mm (0.3149 in.) to 15 mm (0.5905 in.).

 (d)
 For the rivets (10):

 


 -Part Number NAS 1921C05S02.
R 1EFF : 001-003, 051-054, 1 21-61-00Page 808 1 1 May 01/05 1 1 1CES 1


 5. Close-up
________
 Subtask 21-61-00-410-058

 A. Close Access
 (1)
 Put the lever (5) in position on the actuator (2) and install the spacer (4), the bolt (3) and the nut (6).

 (2)
 Make sure that the work area is clean and clear of tool(s) and other items.


 (3) Install the access panel/s (Ref. TASK 53-35-13-400-002). R (a) FOR 9HH
 -191KB R (b) FOR 29HH
 -192KB
 (4) Remove the warning notice(s).
 Subtask 21-61-00-865-068

 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): FOR 9HH 1HH, 2HH, 3HH, 4HH. FOR 29HH 21HH, 22HH, 23HH, 24HH.
 Subtask 21-61-00-862-057
 C. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
R 1EFF : 001-003, 051-054, 1 21-61-00Page 809 1 1 May 01/05 1 1 1CES 1


R R  Attachment and Linkage Components - Ram Air Inlet Figure 803/TASK 21-61-00-991-005
 1EFF : 1 1 1CES  ALL  1 111 21-61-00 Page 810 May 01/98

 

 SENSOR - COMPRESSOR TEMPERATURE (12HH,32HH) - REMOVAL/INSTALLATION
__________________________________________________________________
 TASK 21-61-11-000-001
 Removal of the Compressor Outlet - Temperature Sensor 12HH (32HH)
 WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
 YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

 WARNING : MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM
_______
 FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
 HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.

 NOTE : The procedure is the same for the compressor outlet-temperature sensors
____
 12HH and 32HH.
 
中国航空网 www.aero.cn