-------------------------------------------------------------------------------
R  PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------**ON A/C 106-149, 303-399,  
R  122VU  4HH  Y19  
R  **ON A/C 401-499,  
R R R R R R R  122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC  53HH 55HH 49HH 51HH 56HH 54HH 50HH  W22 W21 X22 X21 Y21 Y20Y18  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499, 
 Subtask 21-63-00-860-054 
 C. Aircraft Maintenance Configuration 
 (1) Pre-condition the Aircraft 
 WARNING : MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN._______ WITH A WARNING PLACARD ATTACHED TO IT. THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT. 
 - do the pre-conditioning with the APU (Ref. TASK 12-33-21-618-001). 
 (2) On the AIR COND panel 30VU make sure that: 
 (a) the PACK FLOW selector is in the NORM position and, 
 (b) the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legend is off). 
 (3) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001). 
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-63-00Page 517 1201-299, 303-399, 401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C 301-399,
 Subtask 21-63-00-860-054-A
 C. Aircraft Maintenance Configuration
 (1) Pre-condition the Aircraft WARNING : MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN.
_______ WITH A WARNING PLACARD ATTACHED TO IT. THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
 -do the pre-conditioning with the APU (Ref. TASK 12-33-21-618-001).
 (2)
 On the AIR COND panel 30VU make sure that:
 (a)
 the ECON FLOW pushbutton switch is in the off position (the ON legend is off) and,
 (b)
 the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legends are off).
 (3)
 Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).
 **ON A/C ALL
 4. Procedure
_________ **ON A/C 001-003, 051-054,
 Subtask 21-63-00-720-050
 A. Functional Test of the Temperature Control System (Test carried out with the APU bleed system)
 WARNING : MAKE SURE THAT THERE ARE NO PERSONS OR EQUIPMENT NEAR THE RAM
_______ AIR OUTLET FLAPS. THE MOVEMENT OF THE RAM AIR OUTLET FLAPS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
 (Ref. Fig. 501/TASK 21-63-00-991-001)
 1EFF : ALL 1 21-63-00Page 518 1 1 Aug 01/05R 1 1 1CES 1
 System Display Pages - Component Location Figure 501/TASK 21-63-00-991-001  
R 1EFF : 1 1 1CES  ALL  1 111 21-63-00 Page 519 Aug 01/05
 NOTE : Make sure that the cabin doors and the cockpit windows are closed
____
 when you do the test.
 NOTE : Due to low pressure in the trim system, with fully closed trim air
____ valves the trim-air pressure regulating-valve symbol (6) can be indicated as closed and show amber. You must ignore this indication for the purposes of this test.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ECAM control panel:  On the System Display (SD): 
 - push the BLEED pushbutton  - the BLEED page comes on, 
 switch.  - the pack flow-control valves symbols 
 (1) move to the open positions and 
 show green. 
 2. On the AIR COND panel 30VU: 
 - put the COCKPIT, the FWD CABIN 
 and the AFT CABIN temperature 
 selectors to the mid (12 
 o'clock) position 24 deg.C. 
 3. On the ECAM control panel:  On the SD: 
 - push the COND pushbutton  - the COND page comes on. 
 switch. 
 4. Wait until the CKPT, the FWD and  On the SD (COND page): 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 5(130)