 (Ref. Fig. 401/TASK 21-63-42-991-001)
 Subtask 21-63-42-420-050
 A. Installation of the Trim-Air Check Valve
 WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK
_______ AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
 WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THIS/THESE
_______ MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
 NOTE : The material 04-007 is a molybdenum disulfide powder.
____ Before you can apply it you must first make it into a paste. To do this you must mix the powder with pure water or white spirit.
 NOTE : The material 06-007 is applied dry.
____
 (1)
 Clean the component interface and/or the adjacent area.

 (2)
 Make sure that the parts retained from the removed component are clean and in the correct condition.


 1EFF : ALL 1 21-63-42Page 413 1 1 Aug 01/05R 1 1 1CES 1


 (3) Do a visual inspection of the trim-air check valve flappers to make sure that they are in a good condition and that they move easily.
 (a) FOR 18HM
 1 Remove the protective covers from the open ends of the ducts
_ (1) and (14), the duct spigot (26) and the sleeve (25).
 2 Make sure that the seals (27) are in a good condition. If
_ necessary replace the seals (27).
 3 Apply a small amount of:
_
 -COMMON GREASE (Material No. 04-007)
 or

 -LUBRICANTS (Material No. 06-007)
 to the seals (27) before you install them.

 4 Make sure that the packings (4) and (12) are in a good
_ condition. If necessary replace the packing (4) and/or the packing (12).
 5 Loosen the bolts (15).
_
 6 Put the packing (4) and the trim-air check valve (9) in
_ position on the duct (14).
 NOTE : Make sure that the flaps open in the direction of the
____ airflow, and that the pin (11) is in the location hole in the duct flange.
 7 Put the packing (12) in position on the flange of the duct
_ (1).
 8 Apply a small quantity of:
_
 -COMMON GREASE (Material No. 04-007)
 or

 -LUBRICANTS (Material No. 06-007) to the seal (27) in the sleeve (25) before you install the duct spigot (26).
 9 Carefully put the duct spigot (26) in position in the sleeve
_ (25).
 NOTE : Turn the sleeve (25) when you put the duct spigot (26)
____ in position. This will help to prevent damage to the seals in the sleeve.
 1EFF : ALL 1 21-63-42Page 414 1 1 Aug 01/05R 1 1 1CES 1


 10 Carefully put the duct (1) in position on the duct (14).
__ NOTE : Make sure that you do not move the packings (4) and
____ (12) and the trim-air check valve (9) when you position the duct (1).
 11 Install the bolts (10), the washers (8) and the nuts (7).
__
 12 Put the support rods (28) and (30) in position in the clevis

__

 (33) and install the bolts (29), the washers (31) and the nuts (32).
 13 Put the bonding strap (3), in position and install the bolt
__ (13), the washer (5) and the nut (6) (Ref. TASK 20-28-00-912-004).
 14 Put the bonding strap (22), in position and install the bolt
__ (23), the washer (21) and the nut (20) (Ref. TASK 20-28-00-912-004).
 (b) FOR 19HM 1 Remove the protective covers from the open ends of the ducts
_
 (2) and (14), the duct spigot (26) and the sleeve (25). 2 Make sure that the seals (27) are in a good condition. If
_
 necessary replace the seals (27).

 3 Apply a small amount of:
_
 -COMMON GREASE (Material No. 04-007)
 or

 -LUBRICANTS (Material No. 06-007)
 to the seals (27) before you install them.

 4 Make sure that the packings (4) and (12) are in a good
_ condition. If necessary replace the packing (4) and/or the packing (12).
 5 Loosen the bolts (15).
_ 6 Put the packing (4) and the trim-air check valve (9) in
_
 position on the duct (14).

 NOTE : Make sure that the flaps open in the direction of the
____ airflow, and that the pin (11) is in the location hole in the duct flange.
 1EFF : ALL 1 21-63-42Page 415 1 1 Aug 01/05R 1 1 1CES 1


 7 Put the packing (12) in position on the flange of the duct
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 5(152)