1.
 Reason for the Job
__________________
 Self Explanatory
 2.
 Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific blanking caps
 No specific blanking plugs
 No specific circuit breaker(s) safety clip(s)
 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power
 53-35-13-000-002  Removal of the Quick-Release Access Panels from the Belly Fairing Structure
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 21-61-11-991-001  Fig. 401
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION ------------------------------------------------------------------------------- 
R  **ON A/C 401-499, 
 21-61-11-991-001-A **ON A/C ALL Fig. 401A 
 3. Job Set-up__________ Subtask 21-61-11-861-050 
 A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). Subtask 21-61-11-865-050 
 B. Open, safety and tag this(these) circuit breaker(s): 
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 12HH  
R  **ON A/C 401-499, 
R  49VU AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 52HH  D08  
R  122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC  1HH 3HH  X22X21  
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC  4HH  Y19
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC  2HH  Y18  
R  **ON A/C 106-149, 303-399,  
R  122VU  4HH  Y19  
R  **ON A/C 401-499,  
R R  122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC  49HH 51HH 50HH  X22 X21Y18 
 **ON A/C ALL 
 FOR 32HH  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC  21HH 23HH 24HH 22HH  W22W21Y21Y20  
R  **ON A/C 401-499, 
R R  122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC  53HH 55HH 56HH 54HH  W22W21 Y21Y20 
 **ON A/C ALL
 Subtask 21-61-11-010-050
 C. Get Access
 (1) Remove the access panel/s (Ref. TASK 53-35-13-000-002).
 (a)
 FOR 12HH
-191KB.
 (b)
 FOR 32HH
 -192KB.
 4. Procedure
_________ R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 (Ref. Fig. 401/TASK 21-61-11-991-001) R **ON A/C 401-499,
 (Ref. Fig. 401A/TASK 21-61-11-991-001-A)
 **ON A/C ALL
 Subtask 21-61-11-020-050
 A. Removal of the Compressor Outlet-Temperature Sensor
 (1)
 Disconnect the electrical connector (2).
 (2)
 Put blanking caps on the disconnected electrical connectors.
 (3)
 Remove and discard the lockwire.
 (4)
 Remove the compressor outlet-temperature sensor (1) and the packing (3).
 (5)
 Remove the packing (3) from the compressor outlet-temperature sensor (1).
 (6)
 Put blanking plugs on the disconnected line ends.
 Compressor Outlet - Temperature Sensor
 Figure 401/TASK 21-61-11-991-001
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 5(16)