R  Subtask 21-61-41-865-058  
R  B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and  
R  tagged  
R  ------------------------------------------------------------------------------- 
R  PANEL  DESIGNATION  IDENT. LOCATION  
R  ------------------------------------------------------------------------------- 
R  FOR 10HM  
R  122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC  1HH  X22  
R  122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC  3HH  X21  
R  **ON A/C 106-149, 303-399,  
R  122VU  4HH  Y19  
R  **ON A/C 106-149, 159-199, 211-299, 301-399,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC  2HH  Y18  
R  **ON A/C 159-199, 211-299, 301-302,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC  4HH  Y19  
R  **ON A/C 106-149, 159-199, 211-299, 301-399,  
R  FOR 11HM  
R  122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC  21HH  W22  
R  122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC  23HH  W21  
R  122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC  24HH  Y21  
R  122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC  22HH  Y20
R  4. Procedure_________  
R  (Ref. Fig. 403/TASK 21-61-41-991-003)  
R  Subtask 21-61-41-420-052  
R  A. Installation of the Back Up Solenoid  
R  (1) Put the back up solenoid (5) in position and install the screw (4),  
R  the washer (6), and the nut (7).  
R  (2) Remove the blanking plugs from the disconnected line ends.  
R  (3) Apply a small quantity of COMMON GREASE (Material No. 04-014A) to the  
R  threaded parts of the connectors (2) and (3).  
R  (4) At the solenoid (5), install the sense line connectors (2) and (3).  
R  (5) TORQUE the sense line connectors (2) and (3) to between 0.9 and 0.915  
R  m.daN (79.64 and 80.97 lbf.in).  
R  (6) Remove the blanking caps and connect the electrical connector (1).  
R  Subtask 21-61-41-865-059  
R  B. Remove the safety clip(s) and the tag(s) and close this(these) circuit  
R  breaker(s):  
R  (1) FOR 25HH  
R  - 1HH, 2HH, 3HH, 4HH.  
R  (2) FOR 40HH  
R  - 21HH, 22HH, 23HH, 24HH.  
R  Subtask 21-61-41-710-052  
R  C. Leak and Operational Test of the Sense Lines Assembly  
R  (1) Do the pre-conditioning through the HP ground connector or with the  
R  APU (Ref. TASK 12-33-21-618-001) (Ref. TASK 12-33-21-618-001).  
R  (2) Do a leak check of the sense line connectors (2) and (3) at the back  
R  up solenoid (5).  
R  NOTE : Leaks are not permitted.____
R  (3) After approx. 15 minutes stop the pre-conditioning (Ref. TASK 12-33- 
R  21-618-001) (Ref. TASK 12-33-21-618-001).  
R  (4) Do the operational test of the pack temperature control system  
R  (Ref. TASK 21-61-00-710-001).  
R  5. Close-up________  
R  Subtask 21-61-41-410-054  
R  A. Close Access  
R  (1) Make sure that the work area is clean and clear of tool(s) and other  
R  items.  
R  (2) Install the access panel(s) (Ref. TASK 53-35-13-400-002).  
R  (a) FOR 25HH  
R  - 191KB.  
R  (b) FOR 40HH  
R  - 192KB.  
R  Subtask 21-61-41-862-052  
R  B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862- 
R  002).
 ACTUATOR - AIR INLET FLAP (8HH,28HH) - REMOVAL/INSTALLATION
___________________________________________________________
 TASK 21-61-51-000-001
 Removal of the Air-Inlet Flap Actuator 8HH and 28HH
 WARNING : MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM
_______
 FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
 HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
 NOTE : The procedure is the same for the air-inlet flap actuator 8HH and 28HH.
____
 1.
 Reason for the Job
 