• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-02-24 09:55来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific circuit breaker(s) safety clip(s)
 No specific 1 ACCESS PLATFORM 2M (6 FT)

R No specific Torque Wrench : range 0.00 to 1.20 m.daN
R (0.00 to 9.00 lbf.ft)

 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 19-009  USA AMS 5687
 LOCKWIRE STAINLESS STEEL ANNEALED 0.5MM DIA
 (Ref. 20-31-00)

 

 C. Expendable Parts
 -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
3  filter 
R  4  packing 
R  5  packing 
6  Filter 
6  Filter 
R
 7  packing 
R
 D. Referenced Information

21-63-52 02B-040 21-63-52 02B-050 21-63-52 02B-06021-63-52 02 -01021-63-52 02 -010A
21-63-52 02 -020
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-33-21-618-001 12-33-21-618-001 21-63-00-720-001 24-41-00-861-002 24-41-00-862-002 25-54-12-000-001
25-54-12-400-001 52-30-00-860-001 52-30-00-860-002 CMM 216210
 21-63-00-991-005
3. Job Set-up
__________ Subtask 21-63-00-861-065
Pre-conditioning through the HP Ground ConnectionPre-conditioning with the APUFunctional Test of the Cockpit and Cabin Temperature Control without CFDS/MCDU.Energize the Aircraft Electrical Circuits from the External PowerDe-energize the Aircraft Electrical Circuits Supplied from the External PowerRemoval of the FWD Cargo Compartment Partition FR34Installation of the FWD Cargo Compartment Partition FR34Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric PumpClose the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump
Fig. 301
 A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002)

 

 Subtask 21-63-00-865-076
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
R  **ON A/C 401-499,
 49VU AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC  52HH  D08 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 122VU AIR COND/ZONE TEMP CTL/28VDC/SYS2 122VU AIR COND/ZONE TEMP CTL/28VDC/SYS1 122VU AIR COND/ZONE TEMP CTL/115VAC/SYS2 122VU AIR COND/ZONE TEMP CTL/115VAC/SYS1  4HK 3HK 2HK 1HK  V20V19V18V17 
R  **ON A/C 401-499,
R R  122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC  53HH 55HH 49HH 51HH 56HH 54HH 50HH  W22W21X22X21 Y21Y20Y18 
**ON A/C ALL
 Subtask 21-63-00-010-059
 C. Get Access (Ref. Fig. 301/TASK 21-63-00-991-005)
 (1) Open the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-001)
 (2) Put the ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.

 

 Trim Air Pressure Valve Filter Figure 301/TASK 21-63-00-991-005
 1EFF : 1 1R 1CES  ALL  1 11 1 21-63-00 Page 304 Aug 01/05

 

 (3) Remove the access panels (Ref. TASK 25-54-12-000-001).
 -131NW
 -131PW
 Subtask 21-63-00-941-061

 D. Safety Precautions
 (1)
 On the air control panel 30VU:

 -make sure that the APU BLEED, the ENG BLEED/1(2) and the PACK/1(2) pushbutton switches are released.
 -put warning notice(s) to tell persons not to operate these pushbutton switches.

 (2)
 On the HP and GP ground connectors:


 -put warning notice(s) to tell persons not to supply the ground air.
 4. Procedure
_________
 Subtask 21-63-00-920-050

 A. Replace/Restore the Filter of the Trim-Air Pressure Regulating Valve (TAPRV)
 (1) For the TAPRV P/N 746A0000-06 and subsequent.
 (a)
 Disconnect the electrical connector (1).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 5(117)