 Make sure that the access panel/s is are removed (Ref. TASK 53-35-13-000-002).
R (a) FOR 15HH
 -191KB. 
R (b) FOR 35HH
 -192KB. 
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-61-12Page 406 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1
 Subtask 21-61-12-865-051 
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged 
R  -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 15HH 122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 1HH X22 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC 3HH X21  
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC  4HH  Y19  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC  2HH  Y18  
R  **ON A/C 106-149, 303-399,  
R  122VU  4HH  Y19  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
 FOR 35HH 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC  21HH 23HH 24HH 22HH  W22W21Y21Y20 
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-61-12Page 407 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1
 4. Procedure
_________
 (Ref. Fig. 401/TASK 21-61-12-991-001)
 Subtask 21-61-12-420-050
 A. Installation of the Compressor Overheat-Temperature Sensor
 (1)
 Make sure that the parts retained from the removed component are clean and in the correct condition.
 (2)
 Make sure that the removed packing (3) is in a good condition. If necessary replace the packing (3).
 (3)
 Remove the blanking plugs from the disconnected line ends.
 (4)
 Clean the component interface and/or the adjacent area.
 (5)
 Apply a small quantity of COMMON GREASE (Material No. 04-012) to the contact faces of the compressor overheat- temperature sensor (1) and to the packing (3).
 (6)
 Put the packing (3) in position on the compressor
 overheat-temperature sensor (1).
 (7)
 Install the compressor overheat-temperature sensor (1) in the pipe assembly (4).
 (8)
 TORQUE the compressor overheat-temperature sensor (1) to between 0.5 and 1.0 m.daN (44.24 and 88.49 lbf.in).
 (9)
 Wipe clean the excess COMMON GREASE (Material No. 04-012) from the compressor overheat-temperature sensor (1) and safety with MISCELLANEOUS (Material No. 19-009).
 (10)
 Remove the blanking caps and connect the electrical connector (2).
 (11)
 Make sure that the work area is clean and clear of tool(s) and other items.
 Subtask 21-61-12-865-053
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 
R (1) FOR 15HH
 -1HH, 2HH, 3HH, 4HH. 
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-61-12Page 408 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1
R  (2) FOR 35HH - 21HH, 22HH, 23HH, 24HH: 
 Subtask 21-61-12-710-050 
 C. Do the operational test of the pack temperature-control system (Ref. TASK 21-61-00-710-001). 
 5. Close-up________ 
 Subtask 21-61-12-410-051 
 A. Close Access 
 (1) Make sure that the work area is clean and clear of tool(s) and other items. 
 (2) Close the access panel/s (Ref. TASK 53-35-13-400-002).  
R  (a) FOR 15HH - 191KB.  
R  (b) FOR 35HH - 192KB. 
 Subtask 21-61-12-862-050 
 B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002). 
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-61-12Page 409 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1
 SENSOR - WATER EXTRACTOR TEMPERATURE (11HH,31HH) - REMOVAL/INSTALLATION
_______________________________________________________________________ TASK 21-61-13-000-001 Removal of the Water-Extractor Temperature Sensors 11HH and 31HH WARNING : MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM
_______ FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
 