COM-913 Tester - Flight Data Recorder System
(Part #: 964-0446-001, Supplier: 97896, A/P Effectivity: 737-300, -400,
-500, -600, -700, -700C, -700ER, -700QC, -800, -900, -900ER)
COM-1807 Tester - DFDAU
(Part #: 2229738-7, Supplier: 98571, A/P Effectivity: 737-200, -200C,
-300, -400, -500, -600, -700, -700C, -700ER, -700QC, -800, -900, -900ER,
-BBJ)
(Part #: 2229738-8, Supplier: 98571, A/P Effectivity: 737-200, -200C,
-300, -400, -500, -600, -700, -700C, -700ER, -700QC, -800, -900, -900ER,
-BBJ)
(Part #: HT717-1, Supplier: 0H231, A/P Effectivity: 737-300, -400, -500,
-600, -700, -700C, -700ER, -700QC, -800, -900, -900ER, -BBJ)
SPL-1808 Cable - Adapter, Teledyne Tester (Use with Teledyne DFDAU Tester)
(Part #: A31007-59, Supplier: 81205, A/P Effectivity: 737-100, -200,
-200C, -300, -400, -500, -600, -700, -700C, -700ER, -700QC, -800, -900,
-900ER, -BBJ)
C. Location Zones
Zone Area
211 Flight Compartment - Left
212 Flight Compartment - Right
564 Left Wing - Spoiler No. 3
664 Right Wing - Spoiler No. 10
D. Prepare for the adjustment.
SUBTASK 27-61-00-861-001
(1) Do this task: Supply Electrical Power, TASK 24-22-00-860-811.
SUBTASK 27-61-00-480-032
(2) Use one of the testers listed below to perform the system test:
NOTE: When a task uses subframe 0 it indicates that a parameter is on all 4 subframes. Some
portable testers do not have a selection switch for subframe 0. On these testers, you
can make a selection of subframes 1 through 4 when a task uses subframe 0.
(a) Do these steps to prepare the Teledyne portable tester, COM-1807.
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-61-00
Page 538
Oct 10/2007
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
1) Remove the shorting plug from the system test plug on the P18 panel.
2) Open these circuit breakers and install safety tags:
CAPT Electrical System Panel, P18-2
Row Col Number Name
C 9 C00109 FLIGHT RECORDER AC
C 10 C00468 FLIGHT RECORDER DC
3) Use the portable tester cable, SPL-1808, to connect the tester to the system test plug.
4) Remove the safety tags and close these circuit breakers:
CAPT Electrical System Panel, P18-2
Row Col Number Name
C 9 C00109 FLIGHT RECORDER AC
C 10 C00468 FLIGHT RECORDER DC
5) Make sure the DFDAU switch on portable tester cable, SPL-1808, is in the OUTPUT TO
DFDR position.
6) Make sure the FDEP switch on the portable tester cable, SPL-1808, is in the
DISCONNECT position.
7) Set the portable tester, COM-1807, to read 256 WPS.
(b) Do the steps below to prepare the Handheld Download flight data recorder system tester,
COM-913 for the system test.
NOTE: The Handheld Download unit can only be used on airplanes with AlliedSignal/
Honeywell solid state flight data recorder (FDR) installed.
1) Open these circuit breakers and install safety tags:
CAPT Electrical System Panel, P18-2
Row Col Number Name
C 9 C00109 FLIGHT RECORDER AC
C 10 C00468 FLIGHT RECORDER DC
2) Connect the Handheld Download flight data recorder system tester, COM-913 to the
connector on the FDR.
3) Remove the safety tags and close these circuit breakers:
CAPT Electrical System Panel, P18-2
Row Col Number Name
C 9 C00109 FLIGHT RECORDER AC
C 10 C00468 FLIGHT RECORDER DC
4) Push the red button on the flight data recorder system tester, COM-913.
5) Set the DSDU switch on the flight data recorder system tester, COM-913.
6) Set the BASE switch on the flight data recorder system tester, COM-913.
SUBTASK 27-61-00-820-039
(3) Put the NORMAL/TEST switch on the flight recorder panel, P5, to the TEST position.
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-61-00
Page 539
Oct 10/2007
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
SUBTASK 27-61-00-820-040
(4) Set the WORD and SUBFRAME as specified.
NOTE: The HHDLU does not have a selection for subframe 0. Make a selection of subframe
ALL or subframe 1 thru 4 when a task uses subframe 0.
(a) If you are adjusting the sensor on spoiler No. 3, set the tester to subframe 0, word 91.
(b) If you are adjusting the sensor on spoiler No. 10, set the tester to subframe 0, word 96.
SUBTASK 27-61-00-865-004
(5) Make sure that this circuit breaker is closed:
CAPT Electrical System Panel, P18-2
Row Col Number Name
C 8 C00544 FLIGHT RECORDER POSITION SENSOR
SUBTASK 27-61-00-863-001
WARNING: KEEP PERSONNEL AND EQUIPMENT AWAY FROM THE FLIGHT CONTROL
SURFACES, THE THRUST REVERSERS, AND THE LANDING GEAR. THESE
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-600-700-800-900 飞机维护手册6 AIRCRAFT MAINTENANCE MANUA(13)