b) The signaling function is ensured by the signaling and warning lamps. For lamp colors and their interpretations, see table below.
Color Interpretation Warning
RED Requires immediate action from the pilot NO CHARGING OF THE STORAGE BATTERY, WHICH THUS BECOMES A SOURCE TO THE USERS ON THE ELECTRICAL LINE
YELLOW Temporary limited functioning of a piece of equipment FUEL PUMP
GREEN Good operating condition of equipment, yet not permanent POWER ON
Each lamp label is marked with the interpretation of the corresponding circuit.
c) The engine control functional group contains the equipment corresponding to the engine-propeller unit, and monitoring the operation of this group. The equipment is recommended by the manufacturer of "ROTAX" engines, with all limitations and markings imposed by this manufacturer.
d) Equipment specifications
Symbol Description Reference Remarks
Functional group generator – startup - signaling
BATT Storage battery PS-12180NB
REG Regulator-rectifier P/N 965 345 included in engine kit
GEN Generator P/N 886 432 included in engine kit
ALi/ARi Electronic ignition block P/N N 965 358 included in engine kit
STARTER Starter P/N 293 152 included in engine kit
CN Capacitor 22000 μF/25V
B01,B02 Protection elements (circuit breakers or fusible plugs) W31-X2M1G-30; AGC 30
SR Start relay P/N 992 819 included in engine kit
V Voltmeter
A Ammeter
PA Airfield socket optional
CL Red signaling lamp 17413
CL1 Green signaling lamp 17412
CL2 Yellow signaling lamp 17411
KS Key switch A-510-2
E01 Master switch 11-15900
S.C. AEROSTAR S.A.
FESTIVAL R40S
BACAU - ROMANIA
AIRPLANE MAINTENANCE MANUAL
Functional group for engine control
DF Fuel quantity indicator 2A4V
T7, T8 Fuel quantity sender 395-5SB
BP Fuel pump FACET 12V 2 . - 4 . PSI
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:FESTIVAL R 40S AIRPLANE MAINTENANCE MANUAL(41)