With pneumatic system air not available (all air sources shut down or with isolation valves closed) but with airplane power on and the water service panel access door closed, water system pressurization by the air compressor is automatic.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. FREIGHTERS ú
38-15-60
ú ú 01 Page 5 ú Jun 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
WATER SYSTEM PRESSURIZATION - MAINTENANCE PRACTICES
___________________________________________________
1. General_______
A. This procedure contains two tasks. The first task removes the pressure from the potable water system components downstream from the overflow/depressurization valve. The second task pressurizes these components.
B. You must also remove the pressure from the pneumatic manifold (AMM 36-00-00/201) if it is necessary to release the pressure upstream from the overflow/depressurization valve. The removal of the pressure from the pneumatic manifold is necessary when you do maintenance on these components of the potable water pressurization system:
(1)
Overflow and depressurization valve
(2)
Check valve
(3)
In-line air filter
TASK 38-15-60-842-008
2. Water System Depressurization_____________________________
A. Access
(1) Access Panel
191FF Access Door, Water Service
B. Procedure
S 862-001
(1)
Open the water service panel door.
S 862-002
(2)
Open these circuit breakers and attach DO-NOT-CLOSE tags.
(a)
P414 Power Distribution Center - Left 1) 414E18 POTABLE WATER VALVES 2) 414R21 WATER SYS AIR COMPRESSOR
(b)
P180 DC Power Distribution Panel 1) 180G15 POTABLE WATER FILL AND OVERFLOW VALVES
(3)
Close the water service panel door.
S 862-003
TASK 38-15-60-862-004
3. Water System Pressurization___________________________
A. Reference
(1) AMM 24-22-00/201, Manual Control
B. Access
(1) Access Panel
191FF Access Door, Water Service
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. FREIGHTERS ú
38-15-60
ú ú 01 Page 201 ú Jun 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
C. Procedure
S 862-005
(1)
Supply electrical power (AMM 24-22-00/201).
S 862-006
(2)
Remove the DO-NOT-CLOSE tags and close these circuit breakers.
(a)
P414 Power Distribution Center - Left
1) 414E18 POTABLE WATER VALVES
2) 414R21 WATER SYS AIR COMPRESSOR
(b)