WASTE TANK CLOSED
DRAIN NIPPLE LEVER
MOUNTING BOLT (8 LOCATIONS)
FWD WASTE TANK SERVICE PANEL (EXAMPLE) OPEN LEVER
A 1 DRAIN CAP FOR THE WASTE TANK
1 AIRPLANES WITH OPEN AND CLOSED LEVERS THE WASTE TANK DRAIN CAP FOR
2 AIRPLANES WITH PUSH-TO-OPEN LEVER B
Waste Tank Drain Nipple Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-32-81
ALL ú ú 01 Page 403 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(2) Access Panels
1104 Forward Toilet Panel
1502 Toilet Service Door
3105R Forward Nose Wheel Well Panel
D. Install the Drain Nipple
S 164-009
(1) Use the solvent, Series 95 (AMM 20-30-95/201) to clean the mounting surfaces and the bolts.
(a) Remove the used sealant from the bolts.
S 034-010
(2) If the heater gasket was removed, do these steps to install a new heater gasket:
(a)
Remove the used wires.
(b)
Splice in the new wires.
(c)
Put the heater gasket in the correct position.
(d)
Make sure the wires are installed correctly.
S 424-011
(3) Engage the drain nipple with the waste duct.
(a) Do these steps to install the drain nipple against the heater gasket: 1) At the service panels with the OPEN/CLOSE levers, install
the drain nipple with the levers in the up position.
2) On airplanes with the PUSH-TO-OPEN levers for the flapper valve, do these steps: a) At the forward service panel, install the drain nipple
with the PUSH-TO-OPEN lever in the aft and up position. b) At the aft service panel, install the drain nipple with the PUSH-TO-OPEN lever in the forward position.
S 434-012
(4) Install the mounting bolts.
(a) Install the nut ring from behind the service panel.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-32-81
ALL ú ú 01 Page 404 ú Jul 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(b)
Put the bolts in the sealant momentarily.
(c)
Install the bolts while the sealant is wet.
S 434-013
(5) Install the clamp to hold the waste drain duct to the drain nipple.
NOTE: Wind teflon tape a minimum of one time around the clamp point
____ of the waste drain duct to make the installation easier. Remove the used teflon tape if it is necessary.
S 414-014
(6)
For the forward service panel, install the access door on the right inner wall of the nose wheel well.
S 414-015
(7)
For the aft service panel, install the aft bulkhead lining panel in the aft cargo compartment.
S 794-023
(8)
Make sure there are no leaks at the service panel when the drain tube is filled with water (AMM 38-32-00/501).
E. Put the Airplane to Its Usual Condition
S 614-017
(1)
Add the chemical precharge to the waste tank and do the remaining steps of the toilet servicing procedure (AMM 12-17-00/301).
S 864-019
(2)
Remove the DO-NOT-CLOSE tag and close this circuit breaker on the load control center panel, P18:
(a) DRAIN HEATER
S 864-022
(3) Remove the electrical power if it is not necessary
(AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-32-81
ALL ú ú 01 Page 405 ú Nov 15/95
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 WATER AND WASTE(91)