38-11-00
ALL ú ú 14 Page 6 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
SPIGOT WATER FAUCETSINK SINKOVERFLOW
LINE
HOT WATER
SUPPLY LINE
COLD WATER
SUPPLY LINE
AIR VENT
LINE COLD WATER SUPPLY LINE
TOILET
OVERBOARD
VENT LINE
WATER HEATER COVER
WATER HEATER WATERTOILET VACUUM
ELECTRICAL
HEATERVENT LINE
CONNECTOR
WATER DRAIN LINE WASTE WATER HEATER PRESSURE
SWITCH RELIEF VALVE
TOILET
TANK
3-WAY SUPPLY & DRAIN VALVE
SUPPLY & DRAIN LINE
MUFFLER
VENT LINE FOR ATMOSPHERIC DISCHARGE
Sink Cabinet Passenger Water System Components (Typical)
Figure 3 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ALL EXCEPT AIRPLANES WITH MODULAR ú
38-11-00
LAVATORIES ú
ú 04 ú BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. Page 7Jul 15/93
A
737-300/400/500MAINTENANCE MANUAL
WATER
FAUCET
ACTUATOR BUTTONS FOR
THE HOT AND COLD WATER ACTUATOR BUTTON FOR
THE WASHBASIN STOPPER
HOT WATER
SUPPLY LINE
COLD WATER
OVER FLOW LINE SUPPLY LINE
WATER
HEATER
WASTE WATER
DRAIN LINE WATER MUFFLER
HEATER
SWITCH
DRAIN VALVE FOR THE LAVATORY
SELECTOR
RUMBOLD LAVATORY (EXAMPLE)
Sink Cabinet Passenger Water System Components Figure 3 (Sheet 2)
A09362
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH RUMBOLD OR YRC MODULAR ú
38-11-00
LAVATORIES ú
ú 09 ú BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. Page 8Mar 15/95
A
737-300/400/500MAINTENANCE MANUAL
B. WATER HEATERS WITH THE TEMPERATURE SELECT SWITCH; The temperature select switch is on the bottom of the water heater. The temperature select switch adjusts the control thermostat to give water that can be heated to one of these temperature ranges. The ranges are: 101°F to 109°F (LOW), 111°F to 119°F (MED) and 121°F to 129°F (HIGH). If the control thermostat fails in the closed position, the overheat switch will cut power to the heater circuit when the temperature reaches approximately 170°F.
C. WATER HEATERS WITHOUT THE TEMPERATURE SELECT SWITCH; The water heater will automatically heat the water to the temperature of approximately 125°F. The control thermostat opens the heater circuit when the temperature goes above 125°F and closes when the temperature goes below 125°F. If the control thermostat does not open at 125°F, the overheat switch will cut power to the heater circuit when the temperature reaches approximately 195°F.
D. An overheat condition requires manually resetting the overheat switch. The overheat switch is beneath the water heater top cover. If the pressure in the heater reaches 140 psi, a pressure relief valve opens. The relief valve closes again at about 130 psi.