38-41-22
ALL ú ú 02 Page 205 ú Nov 12/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 412-036
(21)
Close the aft cargo door.
S 412-037
(22)
Remove electrical power if it is not necessary.
TASK 38-41-22-702-012
4. Pressure Regulator Test (Fig. 202)___________________________________
A. Standard Tools and Equipment
(1)
Gage - Pressure (0-80 psig |0.5 psig)
(2)
Valve - Control (pressure rating 150 psig minimum, 3/8 inch minimum globe type, 15 scfm minimum flow at 50 psid)
(3)
Regulator - Pressure (pressure rated for air source, outlet pressure adjustable, zero to 100 psig, 3/8 inch minimum)
(4)
Filter Air (in-line type)
(5)
Compressed Air Supply (80 psig, 15 scfm minimum)
B. Access
(1) Location Zone
220 Aft Cargo Compartment Equipment Bay
C. Procedure
S 022-044
(1)
Do this task: Pressure Regulator Removal.
S 722-014
(2)
Do a check of the pressure regulator.
(a)
Connect these components to a source of compressed air that does not have oil, as shown in Fig. 202. 1) Water tank pressure regulator 2) Control valve 3) Pressure gages 4) Adjustable Pressure Regulator (0-100 psig) 5) Air filter
(b)
Close the control valve.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-41-22
ALL ú ú 03 Page 206 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
PRESSURE
PRESSURE
GAGE
GAGE
AIR FILTER ADJUSTABLE PRESSURE
PRESSURE REGULATOR
REGULATOR
(100 PSIG
MAXIMUM)
Pressure Regulator Test
Figure 202
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-41-22
ALL ú ú 01 Page 207 ú Jul 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
G38127
A 737-300/400/500MAINTENANCE MANUAL
(c) (d) (e) With the initial pressure at zero psig, slowly increase the pressure to the pressure regulator.Look at the pressure gage while you increase pressure.Keep a record of the upstream pressure and downstream pressure through the pressure regulator. 1) With the upstream pressure from 60 to 65 psig, the downstream pressure must be 23 to 27 psig for the 1552-002-9 pressure regulator and 32 to 38 psig for the 1552-002-19 pressure regulator.
(3) S 782-015If the downstream pressure is not in the pressure range that is specified in the above step, replace the pressure regulator.
(4) S 782-018Reduce the upstream pressure to zero psig.
(5) S 422-045Do the task: Pressure Regulator Installation.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-41-22
ALL ú ú 03 Page 208 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.