38-32-51
ALL ú ú 14 Page 405 ú Jul 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
SEE E
FORWARD LAVATORY COMPARTMENT REMOVE SCREW (4 LOCATIONS)
TOILET TANK SHROUD
TOILET BACK SHROUD
TIMER ACCESS PANEL
ELECTRICAL CONNECTOR
VACUUM VENT LINE GROUND FLUSH LINE TANK OVERBOARD VENT LINE TO TOILET FLUSH TIMER
WASTE WATER DRAIN LINE BONDING JUMPER
DRAIN VALVE CONTROL
TOILET FLUSH CABLE QUICK-DISCONNECT
MOTOR
NUT
(4 LOCATIONS) CATCH BASIN
AFT TOILET
PARTITION TANK
TIEDOWN ROD
OUTBD FWD DRIP (4 LOCATIONS)
PAN FORWARD TOILET TANK
E 1
Toilet Waste Tank Installation
Figure 401 (Sheet 4)
A58080
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-32-51
ALL ú ú 08 Page 406 ú Jul 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
LAVATORY E COMPARTMENT
SEE C
LAVATORY D
COMPARTMENT
TOILETSEE C TANK
SHROUD AFT TOILET SERVICE PANEL
SHROUD FOR WEBER LAVATORIES
AUXILIARY WASTE TANK
SEE D1OR D2 ELECTRICAL
TANK OVERBOARD FLUSH TIMERCONNECTOR
VENT LINE HANDLE
TIMER COLLAR
FASTENERS
GROUND
FLUSH
LINE
CONTROL CABLE QUICK-DISCONNECT
TOILET
TIEDOWN ROD TANK
(2 LOCATIONS) SHROUD
SHROUD FOR RUMBOLD OR YRC LAVATORIES AFT TOILET TANK (EXAMPLE) (RUMBOLD OR YRC LAVATORY SHOWN, WEBER LAVATORIES ALMOST THE SAME)
C
Toilet Waste Tank Installation
Figure 401 (Sheet 5)
E35814
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-32-51
ALL ú ú 13 Page 407 ú Jul 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 014-023
(12) Disengage the control cable for the drain valve at the cable quick-disconnect.
E. Remove the waste tank as follows:
S 024-080
(1)
On the aft waste tank,
remove the tiedown strap.
S 024-082
(2)
On waste tanks with tiedown rods,
do the steps that follow:
(a)
Loosen the fasteners for the tiedown rods.
(b)
Move the tiedown rods away from the waste tank.
S 864-084
(3)
On waste tanks that connect to the auxiliary waste tank, use a lever to alternately lift each end of the waste tank in small graduations until the drain outlets are loosened from their adapters.
S 864-085
(4)
On waste tanks that do not connect to the auxiliary waste tank, turn the waste tank sufficiently to loosen the waste tank from the drain adapter.
S 864-088
CAUTION:_______MAKE SURE YOU LIFT THE WASTE TANK UP SMOOTHLY. IF YOU DO NOT LIFT THE WASTE TANK SMOOTHLY, DAMAGE CAN OCCUR TO THE TANK OUTLET(S) OR THE DRAIN ADAPTER(S).
(5) Lift the waste tank up smoothly.
S 864-090
CAUTION:_______DO NOT SET THE WASTE TANK ON THE TANK OUTLET(S). IF THE TANK OUTLET(S) TOUCH OTHER SURFACES, DAMAGE CAN OCCUR.
(6) Put the waste tank on the supports and make sure the tank outlet(s) do not touch other surfaces.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-32-51
ALL ú ú 10 Page 408 ú Jul 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 024-083
(7) On waste tanks that connect to the auxiliary waste tank, loosen the hose clamp to remove the boot from the floor adapter.
NOTE: Discard the boot.