38-11-00
ALL ú ú 05 Page 9 ú Mar 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
PASSENGER WATER SYSTEM - TROUBLE SHOOTING
_________________________________________
1. Passenger Water System Trouble Shooting Chart
_____________________________________________ ~.............................................................................. | TROUBLE | POSSIBLE CAUSE | ISOLATION PROCEDURE | SOLUTION | ................................................................................
| Low water | Air filter | Examine the air filter | Replace the |
| pressure | element | element for clogs. | element (AMM |
| | | | 38-41-11/401 |
| | | | Servicing) as |
| | | | necessary. |
................................................................................ | | Check valve | When the pressurized air | Replace the | | | | is supplied from the APU | applicable | | | | or the engine bleed air, | check valve | | | | examine the condition of | if necessary. | | | | the applicable check | | | | | valve downstream of the | | | | | source. | | 2..............…..................…............................…...............1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
38-11-00
ALL ú ú 02 Page 101 ú Mar 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
POTABLE WATER SYSTEM - SERVICING
________________________________
1. General_______
A. This procedure contains these tasks:
(1)
Drain the potable water tank.
(2)
Disinfectant the potable water system.
(3)
Manually clean the potable water tank.
B. It is necessary to fully drain the water system before you add a
disinfectant or when you park the airplane in cold weather.
C. If the potable water system is not drained or in normal service a minimum of one time each three days, the growth of bacteria can occur. If bacteria growth continues, and you drink the water, illness can result.
D. The water system should be drained or in normal service at least every 3 days and fresh water added to the system to prevent the growth of bacteria.
E. Use a disinfectant regularly in the potable water system. Use a disinfectant after you complete a maintenance procedure on the water system or if the water system is contaminated.
F. The water system should be disinfected routinely at regular intervals, whenever it is contaminated or when maintenance is performed that could cause contamination.
TASK 38-11-00-683-001
2. Passenger Water System Draining Procedure_________________________________________
A. General
WARNING: IF THE POTABLE WATER SYSTEM IS NOT DRAINED OR IN NORMAL SERVICE
_______ A MINIMUM OF ONE TIME EACH THREE DAYS, THE GROWTH OF BACTERIA CAN OCCUR. IF BACTERIA GROWTH CONTINUES, AND YOU DRINK THE WATER, ILLNESS CAN OCCUR.
(1) The water system should be drained or in normal service at least every 3 days and fresh water added to the system to prevent the growth of bacteria.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 WATER AND WASTE(6)