• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 16:31来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-43-21
 ALL  ú ú 01 Page 404 ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 WATER AND TOILET DRAIN ANTI-ICING SYSTEM -
__________________________________________ DESCRIPTION AND OPERATION
_________________________
 1.  General_______
 A. Toilet Drain Heaters
 (1)  The aft toilet drain has a heater to stop ice formation. The heater is in the drain gasket. The heater operates with 115v ac current. The DRAIN HEATER circuit breaker on the P18 panel controls the heater.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-71-00
 ALL  ú ú 17 Page 1 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

737-300/400/500
MAINTENANCE MANUAL

SEE B
SEE A
TOILET DRAIN OUTLET FITTING
SEE  C 
INBD  FWD 
AFT TOILET SERVICE PANEL GASKET HEATING ELEMENT A  FORWARD TOILET SERVICE PANEL B 

C
Water and Toilet Drain Anti-Icing System Equipment Location Figure 1
H25311
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-71-00
 ALL  ú ú 15 Page 2 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
115V AC
BUS 2

C233
DRAIN

M367 HEATER
AFT TOILET DRAIN HTR

P18-3 CIRCUIT BREAKER PANEL
Water and Toilet Drain Anti-Icing System Schematic
Figure 2

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-71-00
 ALL  ú ú 22 Page 3 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
H25295
A
737-300/400/500MAINTENANCE MANUAL
 WATER AND TOILET DRAIN ANTI-ICING SYSTEM - TROUBLE SHOOTING
___________________________________________________________
 1.  General_______
 A.  Before using the following trouble shooting chart, test the system (Ref 30-71-00 A/T).
 B.  Trouble shooting procedures are based on the assumption that electrical power is available. If remedy in procedure does not correct problem, check wiring continuity using wiring diagram.
 C.  Heating system operates on 115 volts ac.
 D.  There are no indicator lights or gages to verify that the heater system is functioning. Indication of a malfunction will appear as a clogged drain line caused by water freezing in the system.
 E.  If drain line is clogged, check that stoppage is not caused by foreign material or a damaged line.
 2.  Prepare for Trouble Shooting____________________________
 A.  Check that airplane is on landing gear in normal attitude.
 B.  Close DRAIN HEATER circuit breaker on P18 LOAD CONTROL CENTER - LEFT.
 C.  Close LANDING GEAR LIGHTS circuit breaker on P6 LOAD CONTROL CENTER -RIGHT.
 D.  Open STALL WARN-1-AC circuit breaker on P18 LOAD CONTROL CENTER - LEFT.
 E.  Provide electrical power.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-71-00
 ALL  ú ú 02 Page 101 ú Feb 25/85
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
3. Drain Mast Heaters Trouble Shooting
TROUBLE  PROBABLE CAUSE  ISOLATION PROCEDURE  REMEDY 
Toiler drain lines frozen  Loss of electri-cal continuity from circuit breaker to toilet drain heater  Check electrical conti-nuity from applicable breaker to toilet drain heater  Repair circuit as necessary 
 