• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 16:31来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (a)  
Put the switch on the bracket.

 (b)  
Put the clamp around the switch.

 (c)  
Connect the D2558 electrical connector to the switch.

 (d)  
Remove the temporary cap from the fitting.

 (e)  
Put a layer of antisieze compound on the fitting.

 (f)  
Attach the fitting to the switch.


 S 864-014
 (2)  Close the applicable circuit breakers and remove the DO-NOT-CLOSE tags:
 (a)  On the P18 panel
 1)  For the left engine: a) ENG 1 AND WING A/I CONTROL b) ENG 1 COWL ANTI-ICE
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-21-21
 ALL  ú ú 01 Page 403 ú Mar 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 2)  For the right engine:
 a) ENG 2 AND WING A/I CONTROL
 b) ENG 2 COWL ANTI-ICE

 S 864-015
 (3)  Open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  On the P6 panel
 1) PITOT STATIC INDICATION - CAPTAIN
 2) PITOT STATIC INDICATION - F/O

 S 724-016
 (4)  Do a test of the pressure switch circuit.
 (a)  
Make sure the applicable left or right (engine 1 or engine 2) COWL ANTI-ICE light on the P5-11 module is off.

 (b)  
Open the applicable circuit breaker on the P6 panel and attach a DO-NOT-CLOSE tag: 1) For the left engine:

 a) MASTER DIM SEC 1
 2) For the right engine:
 a) MASTER DIM SEC 4


 (c)  
Disconnect the pressure switch connector D2558.

 (d)  
Temporarily connect a wire between pins 1 and 2 of electrical connector D2558.

 (e)  
Remove the DO-NOT-CLOSE tag and close the applicable circuit breaker on the P6 panel: 1) For the left engine:

 a) MASTER DIM SEC 1
 2) For the right engine:
 a) MASTER DIM SEC 4


 (f)  
Make sure the applicable left or right COWL ANTI-ICE light on the P5-11 module comes on.

 (g)  
Open the applicable circuit breaker on the P6 panel and attach a DO-NOT-CLOSE tag: 1) For the left engine:

 a) MASTER DIM SEC 1
 2) For the right engine:
 3) MASTER DIM SEC 4


 (h)  
Remove the wire between pins 1 and 2 of electrical connector D2558.

 (i)  
Connect electrical connector D2558 to the pressure switch.

 (j)  
Remove the DO-NOT-CLOSE tag and close the applicable circuit breaker on the P6 panel: 1) For the left engine:

 a) MASTER DIM SEC 1
 2) For the right engine:
 a) MASTER DIM SEC 4


 (k)  
Make sure the applicable left or right COWL ANTI-ICE light on the P5-11 panel is off.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-21-21
 ALL  ú ú 01 Page 404 ú Nov 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 (5)  S 864-017Remove the DO-NOT-CLOSE tags and close these circuit breakers: (a) On the P6 panel 1) PITOT STATIC INDICATION - CAPTAIN 2) PITOT STATIC INDICATION - F/O
 (6)  S 844-018Remove electrical power if it is not necessary (AMM 24-22-00/201).
 (7)  S 414-019Close the fan cowl on the applicable engine (AMM 71-11-02/201).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-21-21
 ALL  ú ú 01 Page 405 ú Nov 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 INLET COWL TAI OVERHEAT SWITCH - REMOVAL/INSTALLATION
_____________________________________________________
 1.  General_______
 A.  This procedure contains three tasks:
 (1)
The removal of the overheat switch from the inlet cowl
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 防冰和排雨(46)