C. References
(1)
24-22-00/201, Manual Control
(2)
IPC 30-10-00
(3)
SSM 30-11-00
(4)
WDM 30-12-01
D. Access
(1)
Location Zone 101 Control Cabin - Left 102 Control Cabin - Right 302 Left Wing Outboard Leading Edge Including Slats 402 Right Wing Outboard Leading Edge Including Slats 507 Strut 607 Strut
(2)
Access Panel
5727L Access Door Strut
5827R Access Door Strut
6241L Slat Access Panel Removable
6307L Slat Access Panel Removable
6407R Slat Access Panel Removable
6541R Slat Access Panel Removable
E. Procedure
S 865-002
(1) Supply electrical power (Ref 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
30-11-41
ALL ú ú 02 Page 501 ú Jul 15/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 865-003
(2) Make sure these circuit breakers are closed:
(a)
On the P18-3 panel - Load Control Center, Left
1) WING ANTI-ICE VALVE
2) ANTI-ICE CONTROL ENG 1 & WING
(b)
On the P6-3 panel - Load Control Center, Right
1) LANDING GEAR AIR/GND RELAY & LIGHTS
2) NOSE GEAR AIR/GND
S 725-006
(3)
Push each light on the P5-11 module to make sure it comes on.
S 725-005
(4)
Do these steps to make sure the module shows the position of the wing TAI valves correctly:
(a)
Put the WING ANTI-ICE switch in the on position.
(b)
Make sure the L VALVE OPEN and R VALVE OPEN lights come on brightly for 1 to 3 seconds.
(c)
Make sure the L VALVE OPEN and R VALVE OPEN lights are on dimly after 3 seconds.
(d)
Make sure the wing TAI valves open.
(e)
Disconnect electrical connector D732 from the left wing TAI valve.
(f)
Make sure the L VALVE OPEN light is on brightly and
continuously.
(g)
Connect electrical connector D732 to the left wing TAI valve.
(h)
Make sure the L VALVE OPEN light is on dimly and continuously.
(i)
Disconnect electrical connector D734 from the right wing TAI valve.
(j)
Make sure the R VALVE OPEN light is on brightly and
continuously.
(k)
Connect electrical connector D734 to the right wing TAI valve.
(l)
Make sure the R VALVE OPEN light is on dimly and continuously.
(m)
Put the WING ANTI-ICE switch in the off position.
(n)
Make sure the L VALVE OPEN and R VALVE OPEN lights come on brightly for 1 to 3 seconds.
(o)
Make sure the L VALVE OPEN and R VALVE OPEN lights go off.
(p)
Make sure the wing TAI valves close.
(q)
Put the WING ANTI-ICE switch in the on position.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
30-11-41
ALL ú ú 02 Page 502 ú Jul 15/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 485-021
(5) Attach the protractor and adapter to the left thrust lever.
S 725-009
(6) Do these steps to see that the module gets the correct input from
the left throttle switch:
(a) Move the thrust levers to the idle stop.
(b) Set the WING ANTI-ICE switch to ON.
(c) Slowly push the left thrust lever forward.
(d) Make sure that the L VALVE OPEN and R VALVE OPEN lights come on
bright when the left thrust lever is at approximately 32 |1°.
(e) Move the left thrust lever forward to its stop.
(f) Slowly move the left thrust lever aft.
(g) Make sure the L VALVE OPEN and R VALVE OPEN lights become dim
中国航空网 www.aero.cn