30-41-00
ALL ú ú 02 Page 3 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
30-41-00
ALL ú ú 02 Page 4 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
P5-9 WINDOW AND PITOT HEAT PANEL
NOTE: LEFT SIDE SHOWN,RIGHT SIDE SIMILAR
Window Anti-Icing System SchematicFigure 2 (Sheet 1)
A 737-300/400/500MAINTENANCE MANUAL A 737-300/400/500MAINTENANCE MANUAL
P5-9 WINDOW AND PITOT HEAT PANEL M322 LEFT SIDE WINDOW HEAT CONTROL UNIT (E3-3) A13 LEFT SIDE WINDOW NO.2LEFT SIDE SHOWN,RIGHT SIDE SIMILAR
Window Anti-Icing System Schematic
Figure 2 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH THERMAL SWITCH AFTER ú
30-41-00
WINDOW 5 HEATER ú ú 01 Page 5 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH THERMAL SWITCH BEFORE ú
30-41-00
WINDOW 5 HEATER ú ú 01 Page 6 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
3. Window Heat Sensor
__________________
A. The No. 1 and 2 windows each have a heat sensor consisting of a filament of noninsulated resistance wire. The wire is arranged in a single plane coil and imbeded in a thin plastic wafer installed near the lower edge of the window (Fig. 1 and 2) between the outer pane and plastic core. The resistance of the wire is sensitive to temperature and increases as the temperature increases. A change in window temperature causes a change in sensor resistance, providing a signal for the heat control unit. No. 1 and 2 windows have a spare heat sensor mounted adjacent to the primary heat sensor. If the primary sensor fails, the spare sensor may be used.
4. Control Switches
________________
A. There are four window heat control switches, one for each of the No. 1 and 2 windows on each side of the cabin. The switches are four-pole two position ON-OFF toggle switches and are on the overhead panel. The No. 4 and 5 windows are controlled by the respective left or right side window heat switch (Fig. 1 and 2).
5. Control Unit
____________
A. There are four window heat control units, one for each of the window No. 1 and 2 heating systems. The units are located in the E3-3 electrical rack (Fig. 1 and 2).
B. The temperature control unit is a solid state device which performs three functions: overheat control, temperature control including ramp control and shorted sensor protection, and power indication.
C. The control unit overheat circuit, when energized, directs 115-volt ac power from the window anti-ice circuit breaker to the control unit temperature control circuit.
中国航空网 www.aero.cn