F. Prepare for the Test
S 865-003
(1)
Make sure that the No. 2 windows are closed and the handles are latched.
(2)
Supply electrical power (AMM 24-22-00/201).
S 865-002
(3)
Open these circuit breakers and attach DO-NOT-CLOSE tags:
S 865-001
(a) P6 Panel 1) PITOT STATIC INDICATION CAPTAIN 2) PITOT STATIC INDICATION FIRST OFFICER
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
30-41-00
ALL ú ú 02 Page 501 ú Mar 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
Window No. 1 Voltage Test
Figure 501
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
30-41-00
ALL ú ú 01 Page 502 ú Mar 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
G33662
A
737-300/400/500MAINTENANCE MANUAL
3) WINDOW ANTI-ICE L4 & L5
4) WINDOW ANTI-ICE R4 & R5
S 865-004
(4) Set the four WINDOW HEAT switches on the window and pitot heat control module (P5-9) to OFF.
(a) Make sure that all the window heat ON lights (on the window and pitot heat control module) are off.
S 715-006
(5) Set the LIGHTS test switch on the P2 panel to TEST.
(a)
Make sure that the four window ON lights come on.
(b)
Make sure that the four window OVERHEAT lights come on.
(c)
Make sure that the ANTI-ICE light (P7 pilots' lightshield) comes on.
(d)
Release the LIGHTS test switch.
G. No. 1 Left Window Heat Test
S 485-007
(1)
At the No.1 Left window connect an AC voltmeter between the top aft terminal of window and airplane ground. See Fig.501
S 735-008
(2)
Do a check of the window heat operation:
(a)
Set the WINDOW HEAT L FWD switch to ON.
(b)
Make sure that the WINDOW HEAT L FWD ON light comes on in less than 15 seconds after you set the switch to ON.
(c)
Make sure that the voltmeter shows voltage at the window.
S 735-009
(3) Do a check of the window overheat mode:
(a)
Hold the WINDOW HEAT TEST switch (P5-9 module) to OVHT.
(b)
Make sure that the WINDOW HEAT L FWD OVERHEAT light comes on.
(c)
Make sure that the two MASTER CAUTION lights (P7 pilots' lightshield) come on.
(d)
Make sure that the ANTI-ICE light comes on.
(e)
Make sure that the WINDOW HEAT L FWD ON light goes off in less than 70 seconds after you moved the switch to OVHT.
(f)
Make sure that the voltmeter shows no voltage at the window.
(g)
Release the WINDOW HEAT TEST switch.
S 715-048
(4) Do a check of the master caution annunciation:
(a)
Push one of the two MASTER CAUTION lights.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 防冰和排雨(64)