WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______
CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
WARNING : WEAR AND ATTACH A SAFETY HARNESS WHEN YOU WORK ON HIGH SECTIONS. A
_______
FALL CAN INJURE OR KILL YOU.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.
CAUTION : DO NOT CAUSE DAMAGE TO THE SURFACES. THE COMPONENTS ARE MADE OF
_______
CARBONFIBER REINFORCED PLASTIC.
1.
Reason for the Job
__________________
Refer to the MPD TASK: 552004-01
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific warning notices
No specific access platform 3.5 m (11 ft. 6 in.)
98D27309001000 1 TOOL-ELEVATOR NEUTRAL SETTING
98D27903500000 2 PIN-SIDE STICK LOCKING
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-004 USA MIL-T-81533
1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
(Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-10-00-864-001 Depressurize the Green Hydraulic System
29-10-00-864-002 Depressurize the Yellow Hydraulic System
NTM 552004 PB 501
SRM 552100 PB 101
R SRM 552100 PB 201 SRM 552111 PB 001 R 55-20-00-991-001 Fig. 601
3. Job Set-up
__________
Subtask 55-20-00-860-051
A. System Configuration
(1)
Determine the skin panels structure identification of your elevator (Ref. SRM 552111 PB 001).
(2)
Make sure that the elevators are on their lower travel limit stops.
(3)
Make sure that the inspection are is clean and smooth.
Subtask 55-20-00-860-050
B. Depressurize Hydraulic Systems
(1) Depressurize the Green, Yellow and Blue hydraulic systems (Ref. TASK 29-10-00-864-001) (Ref. TASK 29-10-00-864-002) (Ref. TASK 29-10-00-864-002)
Subtask 55-20-00-865-050
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/ELAC1/NORM/SPLY 15CE1 B11 49VU FLIGHT CONTROLS/THS/ACTR/MOT2 19CE2 B09 105VU FLIGHT CONTROLS/ELAC2/STBY SPLY 16CE2 A02 105VU FLT CTL/ELAC1/STBY SPLY 16CE1 A01 121VU FLIGHT CONTROLS/THS ACTR/MOT3 19CE3 Q17 121VU FLIGHT CONTROLS/THS ACTR/MOT1 19CE1 Q16 121VU FLIGHT CONTROLS/ELAC2/NORM/SPLY 15CE2 R20
Subtask 55-20-00-481-050
D. Install Locking Devices
(1)
Put the PIN-SIDE STICK LOCKING (98D27903500000) in the CAPT and F/O side stick controllers.
(2)
Install the TOOL-ELEVATOR NEUTRAL SETTING (98D27309001000) on the elevator.
Subtask 55-20-00-941-050
E. Safety Precautions
(1)
Put the warning notices in the flight compartment to tell persons not to operate the flight controls.
(2)
Put the warning notices in position to tell persons not to operate the hydraulic systems.
(3)
Put the access platform in position at zone 334 for the left hand elevator and/or zone 344 for the right hand elevator.
1EFF : ALL 1 55-20-00Page 603 1 1 Feb 01/04R 1 1 1CES 1
Subtask 55-20-00-860-055
F. Preparation of the Inspection Areas
(1) Make sure that the outer surface of the inspection area is clean and smooth.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE_______ THIS/THESE MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK_______ AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM STABILIZERS 安定面(55)