No specific  corrosion-resistant steel lockwire 0.8 mm (0.032 in.) dia.
 Material No. 02-003  F NSA 307110 TYPE 4
 HYDRAULIC FLUID (PHOSPHATE ESTER BASE)
 (Ref. 20-31-00)

 Material No. 02-003A  F NSA 307110 TYPE 4
 HYDRAULIC FLUID (PHOSPHATE ESTER BASE)
 (Ref. 20-31-00)

 Material No. 02-003B  F NSA 307-110 TYPE 4
 HYDRAULIC FLUID (PHOSPHATE ESTER BASE)
 (Ref. 20-31-00)

 Material No. 02-003C  F NSA 307-110 TYPE IV
 HYDRAULIC FLUID (PHOSPHATE ESTER BASE)
 (Ref. 20-31-00)

 Material No. 02-003D  F NSA 307-110 TYPE IV
 HYDRAULIC FLUID (PHOSPHATE ESTER BASE)
 (Ref. 20-31-00)

 Material No. 05-002 USA MIL-P-8116 PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00) Material No. 07-010 D DA-4-653-91 LACQUER OBSOLETE USE 16-047 (Ref. 20-31-00)
 Material No. 09-018  USA AMS 3267/3
 CORROSION INHIBITING LOW ADHESION SEALANT
 (Ref. 20-31-00)

R
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 32-44-17Page 407 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1R C. Referenced Information


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
12-12-29-611-001  Fill the Hydraulic Fluid Reservoir with a Hand Pump
 29-00-00-910-002  Safety Procedures of the Hydraulic System
 29-10-00-864-002  Depressurize the Yellow Hydraulic System
 29-14-00-614-001  Depressurization of the Hydraulic Reservoirs
 29-23-00-860-001  Disconnection of the Isolation Coupling of the Power
 Transfer Unit (PTU)
 29-23-00-860-002  Connection of the Isolation Coupling of the Power
 Transfer Unit (PTU)
 29-32-11-400-004  Installation of the Hydraulic Pressure Transducer
 (3068GN)
 32-12-00-010-001  Open the Main Gear Doors for Access
 32-12-00-410-001  Close the Main Gear Doors after Access
 32-43-00-710-001  Operational Check of Alternate Braking System
 32-43-00-870-002  Bleeding of the High Pressure Alternate Braking
 System
 32-44-15-400-001  Installation of the Pressure Relief Valve 3067GM
 51-75-13-916-002  Repair to a layer of Corrosion Preventive Compound
 32-44-17-991-001  Fig. 401
 3. Job Set-up__________
 Subtask 32-44-17-860-051

 A. Aircraft Maintenance Configuration
 (1)
 Make sure that the PTU isolation coupling is disconnected (Ref. TASK 29-23-00-860-001).

 (2)
 Make sure that the Yellow hydraulic system is depressurized (Ref. TASK 29-10-00-864-002).

 (3)
 Make sure that the reservoir of the Yellow hydraulic system is depressurized (Ref. TASK 29-14-00-614-001).


R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 32-44-17Page 408 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1 Subtask 32-44-17-865-051


 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU L/G/Y BRK/PRESS/IND 61GG C10 121VU HYDRAULIC/BRAKING AND STEERING/SYS2/SPLY 4GG M36 121VU HYDRAULIC/BRAKING AND STEERING/SYS2/CTL 3GG M35 121VU HYDRAULIC/BRAKING AND STEERING/SYS1/CTL 1GG M34 121VU HYDRAULIC/BRAKING AND STEERING/SYS1/IND AND/SPLY 2GG M33 121VU HYDRAULIC/PARK BRK/CTL/STBY 71GG N37 121VU HYDRAULIC/PARK BRK/CTL/NORM 70GG N36 121VU HYDRAULIC/HYD POWER/Y 3803GX N30 121VU HYDRAULIC/Y HYD/PUMP ENG2/MONG 3700GD Q37 121VU HYDRAULIC/Y HYD/PUMP ENG2/CTL 3701GD Q36 123VU Y HYD/ELEC/PUMP 3802GX AB06 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03
 Subtask 32-44-17-941-053
 C. Make sure the warning notices are in position to tell persons not to pressurize the Yellow hydraulic system: - on the panel 40VU in the cockpit, - on the ground service panel of the Yellow hydraulic system.
 Subtask 32-44-17-560-050
 D. Preparation of the Replacement Component
 (1)
 Remove and discard the lockwire from the check valve (6) on the removed manifold (2).

 (2)
 Remove the check valve (6).


R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 32-44-17Page 409 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1


 (3) Remove and discard the packing (7).
 WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK
_______ AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
 