• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-25 18:04来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (13)
 On the overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch.


 **ON A/C ALL
 Subtask 32-44-00-941-051
 C. Safety Precautions
 (1) Put the warning notice(s) to tell persons no to:
 -pressurize the Green and the Yellow hydraulic systems, - operate the landing gear control lever.
 4. Procedure
_________ **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
 Subtask 32-44-00-720-050
 A. Do this test:
 NOTE : Do not push the brake pedals during the test.

____
 In relation to the ambient temperature (Tamb.), make sure that the pressure read on the accumulator pressure gage is not less than the limits (Plimit) shown below:
 1EFF : ALL 1 32-44-00Page 509 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
| | Plimit | | |----------------------------------------------------------| | Tamb | After 30min | After 45min | After 60min | | |-------------------|-------------------|------------------| | | bar | PSI | bar | PSI | bar | PSI | |------------------|---------|---------|---------|---------|---------|--------| | Tamb > 20 deg.C | 152 | 2200 | 141 | 2050 | 131 | 1900 | | (Tamb > 68 deg.F)| | | | | | | |------------------|---------|---------|---------|---------|---------|--------| |0 <Tamb< 20 deg.C | 159 | 2300 | 148 | 2150 | 138 | 2000 | |(32<Tamb<68 deg.F)| | | | | | | |------------------|---------|---------|---------|---------|---------|--------| |-10<Tamb< 0 deg.C | 176 | 2550 | 165 | 2400 | 159 | 2300 | |(14<Tamb<32 deg.F)| | | | | | | |------------------|---------|---------|---------|---------|---------|--------| | Tamb < -10 deg.C | 183 | 2650 | 176 | 2550 | 169 | 2450 | |(Tamb < 14 deg.F)| | | | | | | -------------------------------------------------------------------------------
If two pressure values out of the three pressure values measured are less than the minimum values, do a check of the system to find the leak (Ref. TSM 32-44-00-810-808).
 NOTE : If the ambient temperature is more than 40 deg.C (104.00 deg.F)
____ and if two of the three pressure values measured are less than the minimum pressure values, do a second test. We recommend that you do the test at an ambient temperature near 20 deg.C (68.00 deg.F).
R **ON A/C 401-499,
R Subtask 32-44-00-720-050-B
R A. Do this test:
R  NOTE : Do not push the brake pedals during the test.____
R In relation to the ambient temperature (Tamb.), make sure that the R pressure read on the accumulator pressure gage is not less than the R limits (Plimit) shown below:
 1EFF : 001-049, 051-099, 101-105, 151-199, 1 32-44-00Page 510 1201-210, 401-499, 1Aug 01/05 1 1 1CES 1 1EFF : ALL 1 32-44-00Page 511 1 1 Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------| | Plimit | | |----------------------------------------------------------| | Tamb | After 30min | After 45min | After 60min | | |-------------------|-------------------|------------------| | | bar | PSI | bar | PSI | bar | PSI | |------------------|---------|---------|---------|---------|---------|--------| | Tamb > 20 deg.C | 138 | 2000 | 124 | 1800 | 114 | 1650 | | (Tamb > 68 deg.F)| | | | | | | |------------------|---------|---------|---------|---------|---------|--------| | 0<Tamb<20 deg.C | 145 | 2100 | 134 | 1950 | 124 | 1800 | |(32<Tamb<68 deg.F)| | | | | | | |------------------|---------|---------|---------|---------|---------|--------| |-10<Tamb<0 deg.C | 165 | 2400 | 152 | 2200 | 145 | 2100 | |(14<Tamb<32 deg.F)| | | | | | | |------------------|---------|---------|---------|---------|---------|--------| | Tamb < -10 deg.C | 176 | 2550 | 169 | 2450 | 159 | 2300 | |(Tamb < 14 deg.F)| | | | | | | -------------------------------------------------------------------------------


R  -------------------------------------------------------------------------------
R  | | PARKING BRAKE NOT APPLIED | 
R  | |----------------------------------------------------------| 
R  | | After 30min | After 45min | After 60min | 
R  | |-------------------|-------------------|------------------| 
R  | | bar | PSI | bar | PSI | bar | PSI | 
R  |------------------|---------|---------|---------|---------|---------|--------| 
R  | Plimit | 190 | 2750 | 185 | 2700 | 182 | 2650 | 
R  |------------------|---------|---------|---------|---------|---------|--------| 
R  If two pressure values out of the three pressure values measured are less 
R  than the minimum values, do a check of the system to find the leak (Ref. 
R  TSM 32-44-00-810-808). 
R  NOTE : If the ambient temperature is more than 40 deg.C (104.00 deg.F)____ 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架7(121)