R  moderate contamination is found 
R  2. Job Set-up Information______________________ 
R  A. Fixtures, Tools, Test and Support Equipment 
R  -------------------------------------------------------------------------------
R  REFERENCE  QTY DESIGNATION 
R  -------------------------------------------------------------------------------
R  No specific  safety barriers 
R  No specific  warning notices 
R  No specific  1 METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES 
R  INC.(CAGE CODE 0U7J1) 
R  B. Consumable Materials 
R  -------------------------------------------------------------------------------
R  REFERENCE  DESIGNATION 
R  -------------------------------------------------------------------------------
R  Material No. 17-003A 
R  BIOCIDE FOR FUEL PRESERVATION (Ref. 20-31-00)

 

R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 12-11-28-650-003 R 12-11-28-650-004 R 12-32-28-281-001 R 12-32-28-281-003 R R 24-41-00-861-002 R R 24-41-00-862-002 R R 28-00-00-910-001 R 28-11-00-600-008 R R 28-25-00-650-001 R 31-60-00-860-001 R 31-60-00-860-002 R 32-00-00-481-001 R R 49-32-11-610-001 R 49-32-11-610-002 R 49-32-41-920-001 R 73-11-10-920-001
R 3. Job Set-up
__________
R Subtask 28-11-00-941-106
R A. Safety Precautions Pressure Refuel with Automatic Control Pressure Refuel with Manual Control Drain Water Content Sample Fuel for Microbiological Contamination Analysis Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power Fuel Safety Procedures Biocidal Shock Treatment for Moderate Contamination -Using Biobor Biocide With a Metered Injection Rig Pressure Defuel EIS Start Procedure EIS Stop Procedure Installation of the Safety Devices on the Landing Gears Servicing of the Fuel Filter (GTCP 36-300) Fuel Filter Element - Removal/Installation (APS 3200) Replacement of the Fuel Filter (8028KM) (131-9(A)) Remove, Inspect and Replace Fuel Filter Element

R WARNING : OBEY THE FUEL SAFETY PROCEDURES.
_______
R NOTE : This procedure is applicable to MICROBIOLOGICAL CONTAMIN. PROTECT.
____ R MATERIALS (Material No. 17-003A) only. The material is Kathon. For R the equivalent procedure with the use of Biobor (Ref. TASK 28-11-R 00-600-008).
R (1) Put the safety barriers in position.
R (2) Make sure that the ground safety locks are installed on the landing R gear (Ref. TASK 32-00-00-481-001).
 1EFF : ALL 1 28-11-00Page 326 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 28-11-00Page 327 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 28-11-00Page 328 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 28-11-00Page 329 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 28-11-00Page 330 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 28-11-00Page 331 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 28-11-00Page 332 1 1 May 01/05 1 1 1CES 1R C. Referenced Information


R  (3) Obey the fuel safety procedures when you do work on the fuel system 
R  (Ref. TASK 28-00-00-910-001). 
R  (4) Put warning notices in the cockpit to tell persons not to operate: 
R  - the aircraft engines 
R  - the flap/slat system 
R  - the fuel system. 
R  Subtask 28-11-00-860-105 
R  B. Aircraft Maintenance Configuration 
R  WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED_______ 
R  BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. 
R  (1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-
R  002). 
R  (2) Do the EIS start procedure (ECAM only) (Ref. TASK 31-60-00-860-001). 
R  (3) On panel 115VU, make sure that the ENG 1 and 2 switches are in the 
R  OFF position. 
R  Subtask 28-11-00-960-058 
R  C. Replace the Fuel Filter Elements 
R  (1) Replace the No. 1 and 2 engine fuel filter elements (Ref. TASK 73-11-
R  10-920-001). 
R  (2) Replace the APU fuel filter element: 
R  - for the 131-9(A) APU (Ref. TASK 49-32-41-920-001) 
R  - for the GTCP 36-300 APU (Ref. TASK 49-32-11-610-001) 
R  - for the APS 3200 APU (Ref. TASK 49-32-11-610-002). 
R  4. Procedure_________ 
R  Subtask 28-11-00-281-056 
R  A. Drain the Water from the Fuel Tanks 
R  (1) Drain the water from all of the fuel tanks (Ref. TASK 12-32-28-281-
R  001).
 