R (7) Let the fuel stay in the tanks for between 12 and 24 hours.
R NOTE : In a high ambient temperature, the soak time must be a minimum____
R of 12 hours. In a low ambient temperature, the soak time must
R be a minimum of 24 hours. AIRBUS recommends that you always
R let the fuel stay in the tanks for 24 hours.
R (8) During the soak time:
R - do not move the aircraft
R - do not operate the fuel pumps or APU
R - do not do water drain tests, a high concentration of biocide will
R be in the sample.
R (9) After the soak time, the fuel and biocide is burned through the APU
R and engines during normal operations.
R NOTE : Obey the engine manufacturers restrictions and guidelines for____
R your aircraft.
R 5. Close-up________
R Subtask 28-11-00-942-115
R A. Removal of Equipment
R NOTE : For disposal of waste fuel, refer to the local regulations.____
R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.
R (2) Remove the warning notice(s).
R (3) Remove the ground support and maintenance equipment, the special and
R standard tools and all other items.
R (4) Remove the safety barriers.
R Subtask 28-11-00-960-066
R B. Replace the Fuel Filter Elements
R NOTE : The fuel filter elements must be replaced again after 50 to 75____
R hours of operation.
R (1) Replace the No. 1 and 2 engine fuel filter elements again (after 50
R to 75 hours operation) (Ref. TASK 73-11-10-920-001).
R (2) Replace the APU fuel filter element again (after 50 to 75 hours
R operation):
R - for the 131-9(A) APU (Ref. TASK 49-32-41-920-001)
R - for the GTCP 36-300 APU (Ref. TASK 49-32-11-610-001)
R - for the APS 3200 APU (Ref. TASK 49-32-11-610-002).
R Subtask 28-11-00-281-062
R C. Contamination Check
R (1) Do the sampling procedure again in less than 10 days (but after a
R minimum of 5 flights) to check for contamination (Ref. TASK 12-32-28-
R 281-003).
R NOTE : AIRBUS recommends that if you get a negligible result, you do____
R not continue to use the biocide treatment.
R TASK 28-11-00-600-010
R Biocidal Preventative Treatment for Aircraft in Long-Term Storage - With Fuel
R Mixed with Biobor Biocide
R 1. Reason for the Job__________________
R Do this procedure only when an aircraft is put in long-term storage of 30
R days or more.
R 2. Job Set-up Information______________________
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油1(100)