1EFF : ALL 1 28-00-00Page 410 1 1 Aug 01/04 1 1 1CES 1 1EFF : ALL 1 28-00-00Page 411 1 1 Aug 01/04 1 1 1CES 1 1EFF : ALL 1 28-00-00Page 412 1 1 Aug 01/04 1 1 1CES 1 Subtask 28-00-00-650-051
R (b) Install the bonding lead (6) with the bolt (5) and the nut (7)
R (Ref. TASK 20-28-00-912-006).
R (2) For joint types (detail B):
R (a) Push the pipe into the rib connectors (9) (one at each end).
R (b) Install the pipe and the rib connectors (9) and attach them with
R the bolts (10) and the nuts (8).
R (c) Install the bonding lead (11) with the bolt (12) and the nut (13)
R (Ref. TASK 20-28-00-912-006).
R (3) For joint types (detail C):
R (a) If it is necessary, install the rib connectors (25) and (19) and
R attach them with the bolts (20) and the nuts (18).
R (b) Make sure that the retaining ring (16) is in the correct
R position.
R (c) Push the pipe (17) into the rib connector (25).
R (d) Attach the pipes with the retaining nuts (15) and (24).
R (e) Install the bonding lead (21) with the bolt (22) and the nut (23)
R (Ref. TASK 20-28-00-912-006).
R (4) For joint types (detail E):
R (a) Make sure that the retaining rings (30) are in their correct
R position.
R (b) Push the pipes into the connector (32) and attach them with the
R retaining nuts (31).
R (c) Install the bonding lead (27) with the bolt (28) and the nut (29)
R (Ref. TASK 20-28-00-912-006).
R (5) To install the fairleads (detail F):
R (a) Put the two halves of the fairlead (37) on the pipe and install
R the bolts (35) and the nuts (36).
R (b) Install the bolts (41), the washers (42) and the nuts (34).
R R (c) Install the bonding lead (39) with the bolt (38) and the nut (40) (Ref. TASK 20-28-00-912-006).
R (6) For joint types (detail G):
R R (a) If it is necessary, install the rib connector (45) and attach it with the bolts (50) and the nuts (51).
R R (b) Make sure that the retaining ring (43) is in the correct position.
R R (c) Push the pipe into the rib connector (45) and attach it with the retaining nut (44).
R R (d) Install the bonding lead (46) with the bolt (47) and the nut (48) (Ref. TASK 20-28-00-912-006).
5. Close-up________
Subtask 28-00-00-410-051
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close access to the applicable fuel tank (Ref. TASK 28-10-00-910-002).
(3) Install the applicable access panels:
(a) For the LH and RH wing (Ref. TASK 57-27-11-400-001), (Ref. TASK 57-27-11-400-002).
(b) If applicable, install the wing-tip (Ref. TASK 57-31-21-400-001).
(c) For FR42, install the access cover 147AZ(148AZ) (Ref. TASK 57-17-11-400-001).
Subtask 28-00-00-710-050
B. Operational Test
(1) Do an operational test of the defuel system (Ref. TASK 28-25-00-710-002).
(2) Do a leak test (Ref. TASK 28-25-00-710-003).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油1(58)