(2)
Do the EIS start procedure (ECAM only) (Ref. TASK 31-60-00-860-001).
(3)
On the ECAM control panel, push (in) the FUEL pushbutton switch to show the FUEL page on the ECAM lower display unit.
Subtask 28-12-00-865-054
E. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FUEL/XFR VALVE1/WING/R 2QP A11
49VU FUEL/XFR VALVE1/WING/L 1QP A10 121VU FUEL/XFR VALVE2/WING/R 4QP M23 121VU FUEL/XFR VALVE2/WING/L 3QP M22
4. Procedure
_________
(Ref. Fig. 402/TASK 28-12-00-991-007) Subtask 28-12-00-040-052
A. De-activation of Overpressure Protector 102QM(103QM)
(1) Open and close the circuit breakers given in the following Table: NOTE : The circuit breakers must be opened and closed in the order
____
given.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-12-00Page 409 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
Transfer Valve Electrical Connector - Overpressure Protector 102QM(103QM)
De-activation/Re-activation
Figure 402/TASK 28-12-00-991-007
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-12-00Page 410 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panel 49VU:
- open circuit breaker 1QP
- wait ten seconds.
2. On the panel 121VU: - left wing fuel LO LEVEL warning is
- open the circuit breaker 3QP shown on the ECAM display unit
- wait ten seconds. - left wing transfer valve indicator on
the ECAM display unit shows the
transfer valve not fully open.
3. On the panel 49VU:
- open the circuit breaker 2QP
- wait ten seconds.
4. On the panel 121VU: - right wing fuel LO LEVEL warning is
- open the circuit breaker 4QP shown on the ECAM display unit
- wait ten seconds. - right wing transfer valve indicator
on the ECAM dispaly unit shows the
transfer valve not fully open.
5. On the panel 49VU:
- close the circuit breaker 1QP.
6. On panel 121VU: - left wing transfer valve indicator on
- close the circuit breaker 3QP. the ECAM display unit shows the
transfer valve fully open.
7. On the panel 49VU:
- close the circuit breaker 2QP.
8. On the panel 121VU: - right wing transfer valve indicator
- close the circuit breaker 4QP. on the ECAM display unit shows the
transfer valve fully open.
(2)
Monitor the fuel quantity indicators on the ECAM display unit. Make sure that the quantity of fuel in the wing tank inner cells increases as fuel transfers from the outer cells.
(3)
Disconnect the electrical connector (1) from each forward transfer valve actuator 9QP(10QP) (2).
(4)
Put blanking caps on the disconnected electrical connectors.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-12-00Page 411 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
(5)
Seal all the disconnected cables in a polythene bag.
(6)
Write an applicable entry in the aircraft technical logbook. NOTE : With the transfer valves electrically disconnected, the FLSS
____ BITE test will fail. The message XFR VALVE OPEN will be shown on the ECAM display unit.
5. Close-up
________ Subtask 28-12-00-410-055
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access panels:
-
FOR 9QP
install 522KB
-
FOR 10QP
install 622KB.
Subtask 28-12-00-860-055
B. Aircraft Configuration
(1) Refuel as necessary (Ref. TASK 12-11-28-650-003).
(2) Do the EIS stop procedure (Ref. TASK 31-60-00-860-002). Subtask 28-12-00-942-061
C. De-energize the Electrical Circuits
(1) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
Subtask 28-12-00-942-060
D. Removal of Equipment
(1)
Remove the safety barriers.